m+Medelevator.RU
← Поиск публикаций
The Journal of molecular diagnostics : JMD · 2023

Clonal Characterization and Somatic Hypermutation Assessment by Next-Generation Sequencing in Chronic Lymphocytic Leukemia/Small Lymphocytic Lymphoma: A Detailed Description of the Technical Performance, Clinical Utility, and Platform Comparison.

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Petrova-Drus Kseniya, Syed Mustafa, Yu Wayne, Hutt Kasey, Zlotnicki Alyssa M, Huang Ying, Kamalska-Cyganik Monika, Maciag Lidia, Wang Meiyi, Ma Yuanyuan G, Ho Caleb, Moung Christine, Yao Jinjuan, Nafa Khedoudja, Baik Jeeyeon, Vanderbilt Chad M, Benhamida Jamal K, Liu Ying, Zhu Menglei, Durham Benjamin, Ewalt Mark D, Salazar Paulo, Rijo Ivelise, Baldi Tessara, Mato Anthony, Roeker Lindsey E, Roshal Mikhail, Dogan Ahmet, Arcila Maria E

Аннотация

Somatic hypermutation status of the IGHV gene is essential for treating patients with chronic lymphocytic leukemia/small lymphocytic lymphoma. Unlike the conventional low-throughput method, assessment of somatic hypermutation by next-generation sequencing (NGS) has potential for uniformity and scalability. However, it lacks standardization or guidelines for routine clinical use. We critically assessed the performance of an amplicon-based NGS assay across 458 samples. Using a validation cohort (35 samples), the comparison of two platforms (Ion Torrent versus Illumina) and two primer sets [leader versus framework region 1 (FR1)] in their ability to identify clonotypic IGHV rearrangement(s) revealed 97% concordance. The mutation rates were identical by both platforms when using the same primer set (FR1), whereas a slight overestimation bias (+0.326%) was found when comparing FR1 with leader primers. However, for nearly all patients this did not affect the stratification into mutated or unmutated categories, suggesting that use of FR1 may provide comparable results if leader sequencing is not available and allowing for a simpler NGS laboratory workflow. In routine clinical practice (423 samples), the productive rearrangement was successfully detected by either primer set (leader, 97.7%; FR1, 94.7%), and a combination of both in problematic cases reduced the failure rate to 1.2%. Higher sensitivity of the NGS-based analysis also detected a higher frequency of double IGHV rearrangements (19.1%) compared with traditional approaches.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты