MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/lbr.0000000000000547

Медицинская библиотека · Journal of bronchology & interventional pulmonology · 2019

Using a Laryngeal Mask Airway During Percutaneous Dilatational Tracheostomy is Safe and Obviates the Need for Paralytics.

Sonti Rajiv, Sanley Michael, Vinayak Ajeet

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bedside percutaneous tracheostomy (PT) placement in critically ill patients is performed in a variety of ways, largely driven by institutional preference. We have recently transitioned to primarily extubating the patient and placing a laryngeal mask airway (LMA) before tracheostomy insertion in lieu of retracting the endotracheal tube (ETT) in place. This allows for lower sedative use and provides a superior view of the operative field. Here, we seek to describe the safety and efficiency of that approach.

METHODS

This is a single-center cross-sectional study from 2014 to 2016 comparing patients who underwent PT with the ETT in place retracted to the proximal larynx versus those who were extubated and had a LMA placed. Procedural length, sedative totals, and safety outcomes were recorded.

RESULTS

In total, 125 patients underwent PT during the study period, 75 via a LMA and 50 via existing ETT. There was no difference in procedural duration (LMA: 53.5±21.4 min vs. ETT: 50.4±16.8; P=0.41), total complications (LMA: 29.3% vs. 16%; P=0.09) or major complications (4% in both groups). Cisatracurium use was significantly lower in the LMA arm (LMA: 1.0±3.6 mg vs. ETT: 11.5±5.9 mg; P<0.01).

CONCLUSION

Replacing the ETT with an LMA before PT is equally safe, does not increase total procedural duration, and all but eliminates the need for paralytic agents.

Для цитирования: Sonti Rajiv, Sanley Michael, Vinayak Ajeet. Using a Laryngeal Mask Airway During Percutaneous Dilatational Tracheostomy is Safe and Obviates the Need for Paralytics.. Journal of bronchology & interventional pulmonology. 2019. DOI: 10.1097/lbr.0000000000000547.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.