m+Medelevator.RU
← Поиск публикаций
Journal of contemporary brachytherapy · 2022

Comparison of vaginal gauze packing technique with or without balloon in high-dose-rate brachytherapy of uterine cervical cancer: A crossover randomized controlled trial.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dhanapalan Rishanthini, Pandjatcharam Jagadesan, Saravanan K, Patil Ninad Harish

Аннотация

PURPOSE: To compare the rectal and bladder doses using two different vaginal packing techniques among uterine cervical cancer patients receiving high-dose-rate (HDR) intracavitary brachytherapy (ICBT).

MATERIAL AND METHODS: Forty-five patients with cervical cancer were randomized to receive two sessions of ICBT using tandem and ring applicator (Varian©), following completion of pelvic external beam radiotherapy treatment. The procedure was performed with vaginal balloon plus gauze packing or vaginal gauze packing alone, each of which was used in one of two sessions. Sequence of the type of vaginal packing was chosen with computer-generated block randomization. A HDR dose of 8.5 Gy was prescribed to point A in all patients. Volumetric dose parameters, such as D0.1cc, D0.5cc, D1cc, and D2cc of the rectum and bladder were compared between the two techniques of vaginal packing.

RESULTS: The mean age of patients was 51 years. Majority (88%) of patients had locally advanced stages of cancer at baseline (stage IIB or more). Rectal doses were significantly less in combined packing technique (D0.1cc: 7.52 Gy vs. 9.02 Gy, p = 0.01; D0.5cc: 6.46 Gy vs. 7.42 Gy, p < 0.01; D1cc: 5.91 Gy vs. 6.7 Gy, p < 0.01; D2cc: 5.29 Gy vs. 5.97 Gy, p < 0.01). Bladder doses were higher in the combined packing technique (D0.1cc: 11.20 Gy vs. 10.76 Gy, p = 0.18; D0.5cc: 9.64 Gy vs. 9.32 Gy, p = 0.56; D1cc: 8.64 Gy vs. 8.36 Gy, p = 0.55; D2cc: 7.56 vs. 7.33 Gy, p = 0.55).

CONCLUSIONS: Combined vaginal packing resulted in statistically significant reduction in rectal radiation dose compared with standard vaginal gauze packing in high-dose-rate brachytherapy of cervix cancer using tandem and ring applicators.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты