DOI 10.1002/jmri.22873

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2011

Diffusion tensor imaging of the anal canal at 3 tesla: feasibility and reproducibility of anisotropy measures.

Goh Vicky, Tam Emily, Taylor N Jane, Stirling J James, Simcock Ian C, Jones Robert Glynne, Padhani Anwar R

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the feasibility and reproducibility of 3-tesla diffusion tensor imaging (DTI) of the anal canal.

MATERIALS AND

METHODS

DTI was performed in 25 men with no clinical history of anal canal disease undergoing MRI for prostate cancer. Analysis of fractional anisotropy (FA), relative anisotropy (RA), and apparent diffusion coefficient (ADC) were determined for the epithelial/subepithelial layer, internal sphincter, external sphincter, and puborectalis. The directionality of diffusion was recorded from color-coded tractography maps. Obturator internus and gluteus maximus served as reference muscles. Mean (SD) of values for FA, RA, and ADC were compared using analysis of variance. Intra and inter-rater agreement and test reproducibility (n = 5) was assessed by Bland-Altman statistics.

RESULTS

Mean (SD) for the epithelial/subepithelial layer, internal, external sphincter, and puborectalis were as follows: FA: 0.283 (0.099); 0.337 (0.049); 0.415 (0.072); and 0.407 (0.062), respectively. RA: 0.241 (0.094); 0.292 (0.050); 0.371 (0.083); 0.361 (0.067), respectively; and ADC: 1.49 (0.23); 1.59 (0.19); 1.51 (0.28); and 1.54 (0.29) × 10(-3) mm(2) /s, respectively. Good overall intra and inter-rater agreement and test-retest reproducibility was noted (coefficient of variation of 4.8-19.4% and 5.9-12.9%, respectively).

CONCLUSION

Anisotropy is evident in the anal canal with good inter-rater agreement and test reproducibility.

Для цитирования: Goh Vicky, Tam Emily, Taylor N Jane, Stirling J James, Simcock Ian C, Jones Robert Glynne, Padhani Anwar R. Diffusion tensor imaging of the anal canal at 3 tesla: feasibility and reproducibility of anisotropy measures.. Journal of magnetic resonance imaging : JMRI. 2011. DOI: 10.1002/jmri.22873.