Reconstruction of the Urethral Sphincter with Dynamic Graciloplasty in a Male Rabbit Model.
Аннотация
INTRODUCTION
The use of artificial urinary sphincters can improve urinary incontinence after radical prostatectomies; however, complications can arise. We hypothesized that dynamic graciloplasty improves urethral sphincter reconstruction.
MATERIALS AND
METHODS
Models of urethral sphincter muscle reconstruction were developed in 5 adult rabbits by wrapping the gracilis muscle flap around the urethra. Intra-urethral pressure was measured in each of the models before reconstruction (control), after reconstruction, and after electrical stimulation of the flap in reconstructed models (stimulated models).
RESULTS
The mean maximum urethral closure pressure was significantly greater in the reconstruction model (69.7 (66.5-115.8) mm Hg) than in the control model (39.2 (33.7-49.6) mm Hg). The mean integral of the urethral pressure and urethral length was also significantly greater in the reconstruction model than in the control model. Furthermore, sphincter tightening was enhanced by the electrical stimulation of the flap.
CONCLUSIONS
Our results support our hypothesis that the functional reconstruction of urethral sphincters using muscle flaps is promising for the treatment of urinary incontinence.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.