A trial of devices for urinary incontinence after treatment for prostate cancer.

Macaulay Margaret, Broadbridge Jackie, Gage Heather, Williams Peter, Birch Brian, Moore Katherine N, Cottenden Alan, Fader Mandy J

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the performance of three continence management devices and absorbent pads used by men with persistent urinary incontinence (>1 year) after treatment for prostate cancer.

PATIENTS AND

METHODS

Randomised, controlled trial of 56 men with 1-year follow-up. Three devices were tested for 3 weeks each: sheath drainage system, body-worn urinal (BWU) and penile clamp. Device and pad performance were assessed. Quality of life (QoL) was measured at baseline and follow-up with the King's Health Questionnaire. Stated (intended use) and revealed (actual use) preference for products were assessed. Value-for-money was gathered.

RESULTS

Substantial and significant differences in performance were found. The sheath was rated as 'good' for extended use (e.g. golf and travel) when pad changing is difficult; for keeping skin dry, not leaking, not smelling and convenient for storage and travel. The BWU was generally rated worse than the sheath and was mainly used for similar activities but by men who could not use a sheath (e.g. retracted penis) and was not good for seated activities. The clamp was good for short vigorous activities like swimming/exercise; it was the most secure, least likely to leak, most discreet but almost all men described it as uncomfortable or painful. The pads were good for everyday activities and best for night-time use; most easy to use, comfortable when dry but most likely to leak and most uncomfortable when wet. There was a preference for having a mixture of products to meet daytime needs; around two-thirds of men were using a combination of pads and devices after testing compared with baseline.

CONCLUSIONS

This is the first trial to systematically compare different continence management devices for men. Pads and devices have different strengths, which make them particularly suited to certain circumstances and activities. Most men prefer to use pads at night but would choose a mixture of pads and devices during the day. Device limitations were important but may be overcome by better design.

Для цитирования: Macaulay Margaret, Broadbridge Jackie, Gage Heather, Williams Peter, Birch Brian, Moore Katherine N, Cottenden Alan, Fader Mandy J. A trial of devices for urinary incontinence after treatment for prostate cancer.. BJU international. 2015. DOI: 10.1111/bju.13016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.