Identification of the Vibrational Optical Coherence Tomography Corneal Cellular Peak.
Аннотация
PURPOSE: Our team previously identified the presence of five corneal resonant frequency (RF) peaks in healthy volunteers using vibrational optical coherence tomography (VOCT). Prior studies have suggested that the ≤100 Hz RF peak represents the cellular element of tissue. The aim of this study was to confirm that this peak reflects the human corneal cellular component using VOCT and histological analysis.
METHODS
Two human research globes were obtained from the same donor, and VOCT measurements were collected from the full-thickness corneas. A microkeratome was then used to create serial-free corneal caps from each cornea, with VOCT performed on the residual stromal bed after each excision. All lamellar sections from both globes were sent for histological analysis to determine cellularity. Cell counts on the specimens were performed by two independent observers.
RESULTS
The average of the normalized ≤100 Hz peak values before lamellar sectioning was significantly higher than the average of this peak values after the first, second, and third cuts (P = 0.023), which was 33.9% less than before any cuts. The cell count values in the first slice were significantly higher than the average cell count values of the three deeper slices (P < 0.001), and the cell count dropped 84.4% after the first slice was removed.
CONCLUSIONS
The findings of this study suggest that the ≤100 Hz corneal peak identified by VOCT corresponds to the cellular component of the cornea.
TRANSLATIONAL RELEVANCE: This work furthers our understanding of the origin of the corneal ≤100 Hz peak identified using VOCT.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.