DOI 10.3390/s22197638

Медицинская библиотека · Sensors (Basel, Switzerland) · 2022

Adaptive Filtering for the Maternal Respiration Signal Attenuation in the Uterine Electromyogram.

Martins Daniela, Batista Arnaldo, Mouriño Helena, Russo Sara, Esgalhado Filipa, Dos Reis Catarina R Palma, Serrano Fátima, Ortigueira Manuel

СтатьяПеревод пока не подготовлен

Аннотация

The electrohysterogram (EHG) is the uterine muscle electromyogram recorded at the abdominal surface of pregnant or non-pregnant woman. The maternal respiration electromyographic signal (MR-EMG) is one of the most relevant interferences present in an EHG. Alvarez (Alv) waves are components of the EHG that have been indicated as having the potential for preterm and term birth prediction. The MR-EMG component in the EHG represents an issue, regarding Alv wave application for pregnancy monitoring, for instance, in preterm birth prediction, a subject of great research interest. Therefore, the Alv waves denoising method should be designed to include the interference MR-EMG attenuation, without compromising the original waves. Adaptive filter properties make them suitable for this task. However, selecting the optimal adaptive filter and its parameters is an important task for the success of the filtering operation. In this work, an algorithm is presented for the automatic adaptive filter and parameter selection using synthetic data. The filter selection pool comprised sixteen candidates, from which, the Wiener, recursive least squares (RLS), householder recursive least squares (HRLS), and QR-decomposition recursive least squares (QRD-RLS) were the best performers. The optimized parameters were L = 2 (filter length) for all of them and λ = 1 (forgetting factor) for the last three. The developed optimization algorithm may be of interest to other applications. The optimized filters were applied to real data. The result was the attenuation of the MR-EMG in Alv waves power. For the Wiener filter, power reductions for quartile 1, median, and quartile 3 were found to be -16.74%, -20.32%, and -15.78%, respectively (p-value = 1.31 × 10-12).

Для цитирования: Martins Daniela, Batista Arnaldo, Mouriño Helena, Russo Sara, Esgalhado Filipa, Dos Reis Catarina R Palma, Serrano Fátima, Ortigueira Manuel. Adaptive Filtering for the Maternal Respiration Signal Attenuation in the Uterine Electromyogram.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22197638.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.