MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2015.11.043

Медицинская библиотека · Urology · 2016

The Use of Three-dimensional Printers for Partial Adrenalectomy: Estimating the Resection Limits.

Srougi Victor, Rocha Bruno A, Tanno Fabio Y, Almeida Madson Q, Baroni Ronaldo H, Mendonça Berenice B, Srougi Miguel, Fragoso Maria C, Chambô Jose L

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To avoid hormonal replacement after partial adrenalectomy (PA), establishing the precise limit of an adrenal gland resection is essential. Herein, we evaluated the use of three-dimensional (3D) adrenal gland printing and volumetry measurement before PA to improve the determination of the remnant gland volume.

METHODS

Concomitant total adrenalectomy and a contralateral PA were performed in a patient with primary macronodular adrenal hyperplasia that exhibited mild hypercortisolism, arterial hypertension, and diabetes. Before surgery, a 3D replica of the adrenal gland to be partially resected was printed and given to the surgeon. The volumetry of the gland was measured by computed tomography 3D image reconstruction.

RESULTS

No postoperative complications were noted. Immediately after the surgery, the patient initiated corticosteroid replacement, which was interrupted 52 days later. At the 6-month follow-up, the patient stopped using medications for diabetes and reduced the number of antihypertensive medications from 5 to 1. The pre- and postoperative serum cortisol levels were, respectively, 28 and 8.7 mcg/dl (n 5-25 mcg/dl). The pre- and postoperative adrenocorticotropic hormone levels were, respectively, <5 and 88 pg/ml (n 7.2-63 pg/ml). The postoperative adrenal volume was 12% of the total preoperative adrenal volume.

CONCLUSION

The use of 3D printing associated with adrenal volumetry might be a useful tool for the surgeon when performing PA, enabling an estimation of the remnant gland volume.

Для цитирования: Srougi Victor, Rocha Bruno A, Tanno Fabio Y, Almeida Madson Q, Baroni Ronaldo H, Mendonça Berenice B, Srougi Miguel, Fragoso Maria C, Chambô Jose L. The Use of Three-dimensional Printers for Partial Adrenalectomy: Estimating the Resection Limits.. Urology. 2016. DOI: 10.1016/j.urology.2015.11.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.