MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-015-3268-2

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2015

Prospective comparison of (68)Ga-DOTATATE and (18)F-FDOPA PET/CT in patients with various pheochromocytomas and paragangliomas with emphasis on sporadic cases.

Archier Aurélien, Varoquaux Arthur, Garrigue Philippe, Montava Marion, Guerin Carole, Gabriel Sophie, Beschmout Eva, Morange Isabelle, Fakhry Nicolas, Castinetti Frédéric, Sebag Frédéric, Barlier Anne, Loundou Anderson, Guillet Benjamin, Pacak Karel, Taïeb David

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Pheochromocytomas/paragangliomas (PHEOs/PGLs) overexpress somatostatin receptors and recent studies have already shown excellent results in the localization of these tumors using (68)Ga-labeled somatostatin analogs ((68)Ga-DOTA-SSA), especially in patients with germline succinate dehydrogenase subunit B gene (SDHB) mutations and head and neck PGLs (HNPGLs). The value of (68)Ga-DOTA-SSA has to be established in sporadic cases, including PHEOs. Thus, the aim of this study was to compare (68)Ga-DOTATATE PET/CT, (18)F-FDOPA PET/CT, and conventional imaging in patients with various PHEOs/PGLs with a special emphasis on sporadic cases, including those located in the adrenal gland.

DESIGN

(68)Ga-DOTATATE, (18)F-FDOPA PET/CT, and conventional imaging (contrast-enhanced CT and MRI with MR angiography sequences) were prospectively performed in 30 patients (8 with SDHD mutations, 1 with a MAX mutation and 21 sporadic cases) with PHEO/PGL at initial diagnosis or relapse.

RESULTS

The patient-based sensitivities were 93 % (28/30), 97 % (29/30), and 93 % (28/30) for (68)Ga-DOTATATE PET/CT, (18)F-FDOPA PET/CT, and conventional imaging, respectively. The lesion-based sensitivities were 93 % (43/46), 89 % (41/46), and 76 % (35/46) for (68)Ga-DOTATATE PET/CT, (18)F-FDOPA PET/CT, and conventional imaging respectively (p = 0.042). (68)Ga-DOTATATE PET/CT detected a higher number of HNPGLs (30/30) than (18)F-FDOPA PET/CT (26/30; p = 0.112) and conventional imaging (24/30; p = 0.024). (68)Ga-DOTATATE PET/CT missed two PHEOs of a few millimeters in size and a large recurrent PHEO. One lesion was considered false-positive on (68)Ga-DOTATATE PET/CT and corresponded to a typical focal lesion of fibrous dysplasia on MRI. Among the 11 lesions missed by conventional imaging, 7 were detected by conventional imaging with knowledge of the PET results (4 HNPGLs, 2 LNs, and 1 recurrent PHEO).

CONCLUSION

(68)Ga-DOTATATE PET/CT is the most sensitive tool in the detection of HNPGLs, especially SDHD-related tumors, which may be very small and fail to concentrate sufficient (18)F-FDOPA. The present study further expands the use of (68)Ga-DOTATATE for all patients with HNPGLs, regardless of their genotype. (68)Ga-DOTATATE PET/CT may be inferior to (18)F-FDOPA PET/CT in the detection PHEOs.

Для цитирования: Archier Aurélien, Varoquaux Arthur, Garrigue Philippe, Montava Marion, Guerin Carole, Gabriel Sophie, Beschmout Eva, Morange Isabelle, Fakhry Nicolas, Castinetti Frédéric, Sebag Frédéric, Barlier Anne, Loundou Anderson, Guillet Benjamin, Pacak Karel, Taïeb David. Prospective comparison of (68)Ga-DOTATATE and (18)F-FDOPA PET/CT in patients with various pheochromocytomas and paragangliomas with emphasis on sporadic cases.. European journal of nuclear medicine and molecular imaging. 2015. DOI: 10.1007/s00259-015-3268-2.