Pharmacological validation of a telemetric model for the measurement of bronchoconstriction in conscious rats.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ewart Lorna C, Haley Michael, Bickerton Sue, Bright Jonathan, Elliott Katherine, McCarthy Alan, Williams Lisa, Ricketts Sally-Ann, Holland Tom, Valentin Jean-Pierre

Аннотация

INTRODUCTION: Telemetric measurement of intra-pleural pressure in conscious animals that are restrained in head-out plethysmography chambers enables determination of airway resistance. Originally proposed over 10 years ago, pharmacological validation of this technique is limited. Here airway resistance in conscious, instrumented rats was compared to measurement in anaesthetised rats via a fluid filled oesophageal catheter following administration of two different pharmacological agents.

METHODS: Male rats were implanted with telemetry devices and were trained to accept the restraint of head-out plethysmography chambers. A separate group of male rats were anaesthetised, placed in a body-enclosed plethysmography chamber and were prepared with a tracheal, oesphageal and jugular vein cannulae. Methacholine or NECA were given intravenously and changes in ventilation and airway resistance were measured.

RESULTS: The pressure signal obtained in the telemetered rats was found to be extremely variable. Variability was confounded by excessive struggling, particularly during the infusion periods. Misplacement of the pressure sensitive catheter tip and prior habituation to the chamber were not factors in signal variability. Consequently, no dose-response relationship to either pharmacological agent was established in this model. Dose-dependent increases in resistance to both methacholine and NECA were measured in anaesthetised rats using body-enclosed plethysmography.

DISCUSSION: Given the variability of the pressure signal within and between rats, the feasibility of a model in conscious rats for the measurement of airway resistance is questioned. Improved restraint methods or alternative models in conscious animals should therefore be explored. In the meantime, assessment of airway resistance is best confined to the anaesthetised rat.