MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2009.01.027

Медицинская библиотека · The Journal of surgical research · 2009

Autologous blood pleurodesis in rats to elucidate the amounts of blood required for reliable and reproducible results.

Ozpolat Berkant, Gazyagci Serkal, Gözübüyük Alper, Ayva Sebnem, Atinkaya Cansel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pleurodesis is used in the treatment of spontaneous pneumothorax or refractory pleural effusions of different etiologies. Several agents have been employed, but many questions remain unanswered about their effectiveness and toxicity. Use of autologous blood pleurodesis in clinical practice has been described in the literature without any clear consensus regarding its efficacy. Experimental studies using this technique are limited to a single study in rabbits. We performed a prospective, randomized, observer-blinded, controlled study to evaluate the safety and efficacy of increasing doses of autologous blood pleurodesis in a novel rat model.

MATERIALS AND

METHODS

Twenty-eight albino Wistar rats were divided into four groups. Groups 1, 2, and 3 were the study groups and group 4 was the control group, with seven animals in each group. Groups 1, 2, and 3 were given autologous blood, 1 mL/kg, 2 mL/kg, 3 mL/kg, respectively, and group 4 (control) was given only 2 mL/kg saline intrapleurally. The rats were sacrificed on postoperative day 30. The surfaces were graded by macroscopic (visible adhesion formation) and microscopic (inflammation and fibrosis) examination.

RESULTS

Macroscopically, group 2 and group 3 developed significantly more adhesions; 3 mL/kg autologous blood produced the most significant pleurodesis with generalized adhesions seen between visceral, parietal, and mediastinal pleura. Microscopic examination showed that all study groups developed an inflammatory response at the site of blood injection. There were no pathologic changes in ipsilateral and contralateral lung parenchyma.

CONCLUSIONS

Autologous blood at doses 2-3 mL/kg were shown to be effective to produce adhesions in 30 d, and the results were highly reproducible in all rats. We propose that the occasional negative results obtained in humans may be related to an insufficient amount of injected blood, as observed in our rat model.

Для цитирования: Ozpolat Berkant, Gazyagci Serkal, Gözübüyük Alper, Ayva Sebnem, Atinkaya Cansel. Autologous blood pleurodesis in rats to elucidate the amounts of blood required for reliable and reproducible results.. The Journal of surgical research. 2009. DOI: 10.1016/j.jss.2009.01.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.