MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2022.02.018

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2022

Clinical necessity of multi-image based (4DMIB) optimization for targets affected by respiratory motion and treated with scanned particle therapy - A comprehensive review.

Knopf Antje-Christin, Czerska Katarzyna, Fracchiolla Francesco, Graeff Christian, Molinelli Silvia, Rinaldi Ilaria, Rucincki Antoni, Sterpin Edmond, Stützer Kristin, Trnkova Petra, Zhang Ye, Chang Joe Y, Giap Huan, Liu Wei, Schild Steven E, Simone Charles B, Lomax Antony J, Meijers Arturs

СтатьяОбзорПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

4D multi-image-based (4DMIB) optimization is a form of robust optimization where different uncertainty scenarios, due to anatomy variations, are considered via multiple image sets (e.g., 4DCT). In this review, we focused on providing an overview of different 4DMIB optimization implementations, introduced various frameworks to evaluate the robustness of scanned particle therapy affected by breathing motion and summarized the existing evidence on the necessity of using 4DMIB optimization clinically. Expected potential benefits of 4DMIB optimization include more robust and/or interplay-effect-resistant doses for the target volume and organs-at-risk for indications affected by anatomical variations (e.g., breathing, peristalsis, etc.). Although considerable literature is available on the research and technical aspects of 4DMIB, clinical studies are rare and often contain methodological limitations, such as, limited patient number, motion amplitude, motion and delivery time structure considerations, number of repeat CTs, etc. Therefore, the data are not conclusive. In addition, multiple studies have found that robust 3D optimized plans result in dose distributions within the set clinical tolerances and, therefore, are suitable for a treatment of moving targets with scanned particle therapy. We, therefore, consider the clinical necessity of 4DMIB optimization, when treating moving targets with scanned particle therapy, as still to be demonstrated.

Для цитирования: Knopf Antje-Christin, Czerska Katarzyna, Fracchiolla Francesco, Graeff Christian, Molinelli Silvia, Rinaldi Ilaria, Rucincki Antoni, Sterpin Edmond, Stützer Kristin, Trnkova Petra, Zhang Ye, Chang Joe Y, Giap Huan, Liu Wei, Schild Steven E, Simone Charles B, Lomax Antony J, Meijers Arturs. Clinical necessity of multi-image based (4DMIB) optimization for targets affected by respiratory motion and treated with scanned particle therapy - A comprehensive review.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2022. DOI: 10.1016/j.radonc.2022.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.