MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12880-021-00725-x

Медицинская библиотека · BMC medical imaging · 2022

Purposeful use of multimodality imaging in the diagnosis of caseous mitral annular calcification: a case series report.

Sveric Krunoslav Michael, Platzek Ivan, Golgor Elena, Hoffmann Ralf-Thorsten, Linke Axel, Jellinghaus Stefanie

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Caseous mitral annular calcification (CMAC) is a rare liquefactive variant of mitral annular calcification (MAC) and superficially mimics a cardiac vegetation or abscess. CMAC is viewed as a benign condition of MAC, while MAC has clinical implications for patients' lives. Correctly diagnosing CMAC is essential in order to avoid unnecessary interventions, cardiac surgery or even psychological suffering for the patient.

CASE PRESENTATION: We report on 6 patients with suspected intra-cardiac masses of the mitral annulus that were referred to our institution for further clarification. A definitive diagnosis of CMAC was achieved by combining echocardiography (Echo), cardiac magnetic resonance imaging (MRI) and cardiac computed tomography (CT) for these patients. Echo assessed the mass itself and possible interactions with the mitral valve. MRI was useful in differentiating the tissue from other benign or malign neoplasms. CT revealed the typical structure of CMAC with a "soft" liquefied centre and an outer capsule with calcification.

CONCLUSION

CMAC is a rare condition, and most clinicians and even radiologists are not familiar with it. CMAC can be mistaken for an intra-cardiac tumour, thombus, vegetation, or abscess. Non-invasive multimodality imaging (i.e. Echo, MRI, and CT) helps to establish a definitive diagnosis of CMAC and avoid unnecessary interventions especially in uncertain cases.

Для цитирования: Sveric Krunoslav Michael, Platzek Ivan, Golgor Elena, Hoffmann Ralf-Thorsten, Linke Axel, Jellinghaus Stefanie. Purposeful use of multimodality imaging in the diagnosis of caseous mitral annular calcification: a case series report.. BMC medical imaging. 2022. DOI: 10.1186/s12880-021-00725-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.