MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15330338211059937

Медицинская библиотека · Technology in cancer research & treatment · 2021

Correlation Between Average Segment Width and Gamma Passing Rate as a Function of MLC Position Error in Volumetric Modulated Arc Therapy.

Moon Young Min, Bae Sang Il, Han Moo Jae, Jeon Wan, Yu Tosol, Choi Chul Won, Kim Jin Young

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study analyzed the correlation between the average segment width (ASW) and gamma passing rate according to the multi-leaf collimator (MLC) position error.

METHOD: To evaluate the changes in the gamma passing rate according to the MLC position error, 21 volumetric modulated arc therapy (VMAT) plans were generated using pelvic lymph node metastatic prostate cancer patient's data which is sensitive to MLC position errors as they involve several long, narrow, irregular fields. The ASW for each VMAT plan was calculated using our own code developed using Visual Basic for Applications (VBA). The gamma passing rate of the VMAT plan according to the MLC position error was evaluated using ArcCHECK (Sun Nuclear, Melbourne, FL, USA) while inducing symmetric MLC position errors in 0.25 mm intervals from -1 mm to +1 mm in the infinity medical linear accelerator (Elekta AB, Stockholm, Sweden). Finally, we examined the correlation between the change in the passing rate (γgradient) due to the MLC position error and the ASW in VMAT through linear regression analysis using the least squares method.

RESULTS

The ASW and γgradient were found to have a linear correlation according to the MLC position error, and the coefficient of determination was 0.88. For a 1 mm position error of MLC in VMAT, the gamma passing rate improved by approximately 11.9% as the ASW increased by 10 mm.

CONCLUSION

These results are expected to be employed as guidelines to minimize the dose uncertainty due to MLC position error in VMAT.

Для цитирования: Moon Young Min, Bae Sang Il, Han Moo Jae, Jeon Wan, Yu Tosol, Choi Chul Won, Kim Jin Young. Correlation Between Average Segment Width and Gamma Passing Rate as a Function of MLC Position Error in Volumetric Modulated Arc Therapy.. Technology in cancer research & treatment. 2021. DOI: 10.1177/15330338211059937.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.