BACKGROUND

Transoral endoscopic thyroidectomy provides access via the oral vestibule and gas insufflation to provide reliable remote access surgery to perform a total thyroidectomy. The da Vinci SP (Intuitive Surgical Inc., Sunnyvale, CA, USA) is a next generation flexible single port system that offers unique advantages over previous robotic rigid systems. Here we sought to evaluate the feasibility of performing transoral thyroidectomy with this next generation flexible robotic system.

METHODS

Cadaveric dissection with gas insufflation to test the feasibility of performing transoral thyroidectomy with the da Vinci SP.

RESULTS

A 2 cm incision was made in the oral vestibule and the working space created with a 1cm central port and two lateral 5 mm ports. Then an extra small wound protector (Applied Medical, Rancho Santa Margarita, CA) was placed through the central incision after closure of the 5 mm ports. The robotic system was then deployed through the wound protector while insufflation was maintained at ~6 mmHg. Three instrument arms were deployed. A fenestrated bipolar was used to grasp the thyroid gland while Maryland bipolars and monopolar scissors were used to mobilize each hemi lobe of the thyroid. The recurrent laryngeal nerves were seen and preserved bilaterally. After completion of the surgery and removal of the wound protector the vestibular incision was measured to be 3 cm. Further dissection to identify the mental nerves identified each nerve to be >1 cm from the lateral extent of the central incision.

CONCLUSIONS

In summary, it is feasible to perform a total thyroidectomy with gas insufflation utilizing this next generation flexible robotic system. Further evaluation will be needed to validate the clinical applicability of this technique.

Для цитирования: Chan Jason Y K, Koh Yoon W, Richmon Jeremy, Kim Jaewook, Holsinger F Christopher, Orloff Lisa, Anuwong Angkoon. Transoral thyroidectomy with a next generation flexible robotic system: A feasibility study in a cadaveric model.. Gland surgery. 2019. DOI: 10.21037/gs.2019.10.13.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.