Аннотация

BACKGROUND

To date, several meta-analyses and systematic reviews have reported data about the prevalence and risk of malignancy of thyroid incidentalomas detected by different PET radiopharmaceuticals.

OBJECTIVE

This article aims to summarize the published evidence-based data about the prevalence and risk of malignancy of thyroid incidentalomas detected by different PET radiopharmaceuticals.

METHODS

A comprehensive computer literature search of systematic reviews and meta-analyses published up to July 2019 in PubMed/MEDLINE and Cochrane library databases regarding the prevalence and risk of malignancy of thyroid incidentalomas detected by different PET radiopharmaceuticals was carried out.

RESULTS

We have summarized the data about prevalence and risk of malignancy of thyroid incidentalomas detected by different PET radiopharmaceuticals (fluorine-18 fluorodeoxyglucose, radiolabelled choline and prostate-specific membrane antigen) taking into account 8 evidence-based articles.

CONCLUSION

Evidence-based data demonstrated that thyroid incidentalomas detected by different PET radiopharmaceuticals are not infrequent and their risk of malignancy is not negligible, in particular if focal pattern is evident at PET, thus requiring further clinical and instrumental evaluation.

Для цитирования: Signore Giovanni, Albano Domenico, Giovanella Luca, Bertagna Francesco, Treglia Giorgio. Evidence-Based Data About Prevalence and Risk of Malignancy of Thyroid Incidentalomas Detected by Different PET Radiopharmaceuticals.. Current radiopharmaceuticals. 2020. DOI: 10.2174/1874471012666191212115732.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.