MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jips.jips_327_21

Медицинская библиотека · Journal of Indian Prosthodontic Society · 2022

A randomized controlled trial for evaluation of bone density changes around immediate functionally and nonfunctionally loaded implants using three-dimensional cone-beam computed tomography.

Singh Kamleshwar, Chand Pooran, Chaurasia Akhilanand, Solanki Neeti, Pathak Anupama

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: The aim of this study was to compare and assess bone density changes around immediate functionally and nonfunctionally loaded implants.

SETTINGS AND

DESIGN

In vivo comparative study.

MATERIALS AND

METHODS

Sixty participants selected based on the predetermined inclusion and exclusion criteria received single tooth implants in mandible under two implant loading protocols: Immediate functionally loaded (IFL) and immediate nonfunctionally loaded (INFL). Randomization was done by computer-aided simple randomization procedure. Self-tapering, aggressive SLA implants were placed in the single tooth edentulous sites of mandible in both the groups. Three-dimensional cone-beam computed tomography (3D CBCT) was taken at baseline, 3 and 6 months postimplant placement. Quantitative analysis of the bone density was performed using 3D CBCT in three areas around the implants at crestal, middle, and apical regions of implants.

STATISTICAL ANALYSIS USED: Quantitative data were summarized as mean ± standard deviation. Statistical analyses were performed using the SPSS software version 21.0 (SPSS Inc., Chicago, IL, USA) by unpaired t-test.

RESULTS

Bone density changes after implant placement in IFL group from baseline to 3 months were; crestal region (314.18 ± 71.69), middle (278.23 ± 70.17), apical (274.70 ± 59.79) and changes from 3 to 6 months were; crestal (-105.55 ± 39.60), middle (-114.80 ± 41.46), apical (-141.88 ± 69.58). Bone density changes after implant placement in INFL group from baseline to 3 months were crestal region (199.42 ± 47.97), middle (56.91 ± 10.39), apical (200.98 ± 67.43) and changes from 3 to 6 months were; crestal (-194.38 ± 75.30), middle (-204.40 ± 63.75), apical (-191.28 ± 62.33).

CONCLUSIONS

It was concluded that INFL implant group showed better bone density when compared to IFL implant group.

Для цитирования: Singh Kamleshwar, Chand Pooran, Chaurasia Akhilanand, Solanki Neeti, Pathak Anupama. A randomized controlled trial for evaluation of bone density changes around immediate functionally and nonfunctionally loaded implants using three-dimensional cone-beam computed tomography.. Journal of Indian Prosthodontic Society. 2022. DOI: 10.4103/jips.jips_327_21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.