Brachytherapy · 2014
Three-dimensional treatment planning for vaginal cuff brachytherapy: dosimetric effects on organs at risk according to patients position.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Iatì Giuseppe, Pontoriero Antonio, Mondello Stefania, Brogna Anna, Di Pasquale Andrea, Ielo Isidora, Potami Antonio, Messina Giovanna, De Renzis Costantino, Pergolizzi Stefano
Аннотация
PURPOSE: Aim of this study was to evaluate dose distribution within organs at risk (OARs) and planning target volume (PTV) based on three-dimensional treatment planning according to two different setup positions in endometrial carcinoma patients submitted to postoperative brachy-radiotherapy on vaginal vault.
METHODS AND MATERIALS: Patients with endometrial cancer necessitating of adjuvant brachytherapy on vaginal vault were enrolled. Pelvic computed tomography studies were prospectively obtained in two different setup positions: extend legs (A position) and gynecological (B position). Contoured OARs were bladder, rectum, and small bowel. The PTV was identified as applicator's surface with an isotropic 5-mm margin expansion. Radiation dose delivered in 1 cc (D1cc) and 2 cc (D2cc) of OAR were calculated.
RESULTS: Coverage of PTV and values of D1cc and D2cc obtained for bladder and small bowel were similar in the two positions. For rectum, both D1cc and D2cc had statistically significant lower values in A with respect to B position.
CONCLUSIONS: Both in A and B positions, radiation doses delivered do not exceed the dose constraints. However, A setup seems to significantly reduce doses to rectum while obtaining the same PTV coverage. The findings from our study provide evidence supporting the use of A position setup for delivering vaginal vault brachytherapy.
METHODS AND MATERIALS: Patients with endometrial cancer necessitating of adjuvant brachytherapy on vaginal vault were enrolled. Pelvic computed tomography studies were prospectively obtained in two different setup positions: extend legs (A position) and gynecological (B position). Contoured OARs were bladder, rectum, and small bowel. The PTV was identified as applicator's surface with an isotropic 5-mm margin expansion. Radiation dose delivered in 1 cc (D1cc) and 2 cc (D2cc) of OAR were calculated.
RESULTS: Coverage of PTV and values of D1cc and D2cc obtained for bladder and small bowel were similar in the two positions. For rectum, both D1cc and D2cc had statistically significant lower values in A with respect to B position.
CONCLUSIONS: Both in A and B positions, radiation doses delivered do not exceed the dose constraints. However, A setup seems to significantly reduce doses to rectum while obtaining the same PTV coverage. The findings from our study provide evidence supporting the use of A position setup for delivering vaginal vault brachytherapy.