PURPOSE: Patients express their discomfort by subjective complaints, which may not clearly express the extent of their discomfort. This study noninvasively and objectively quantified ocular discomfort, a form of feeling, from the prefrontal cortex by functional near-infrared ray spectroscopy topography.

METHODS

This case-controlled study enrolled six dry eye patients (male:female, 1:1; 51.8 ± 15.9 years) with ocular discomfort and six normal controls (male:female, 1:1; 48.8 ± 15.2 years). Ocular discomfort was created by Schirmer 1 test in normal controls. The extent of prefrontal cortex activity was evaluated as the number of signal-positive channels using the system by using an eye-opening task with spontaneous blinking in the dark. Changes in the signal-positive channels count by lubricant or anesthetics instillation were analyzed.

RESULTS

Low prefrontal cortex activation was detected in normal controls without ocular discomfort, and high activation was detected in both normal controls and dry eye with ocular discomfort. Prefrontal cortex activity was confirmed with ocular discomfort when the eyes were open, decreased with lubricant, and almost disappeared with anesthetic for all participants.

CONCLUSIONS

These changes in the prefrontal cortex activity exhibited a significant correlation to subjective complaint scores, suggesting that such discomfort may be objectively quantifiable, independent of subjective expressions.

Для цитирования: Ono Masafumi, Takano Yoji, Haida Munetaka. Objective Ocular Discomfort: Noninvasive Evaluation by Functional Near-Infrared Ray Spectroscopy.. Investigative ophthalmology & visual science. 2018. DOI: 10.1167/iovs.18-24840.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.