MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11548-023-03051-5

Медицинская библиотека · International journal of computer assisted radiology and surgery · 2024

Improved subcutaneous edema segmentation on abdominal CT using a generated adipose tissue density prior.

Liu Jianfei, Shafaat Omid, Bhadra Sayantan, Parnell Christopher, Harris Ayden, Summers Ronald M

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Edema, or swelling, is a common symptom of kidney, heart, and liver disease. Volumetric edema measurement is potentially clinically useful. Edema can occur in various tissues. This work focuses on segmentation and volume measurement of one common site, subcutaneous adipose tissue.

METHODS

The density distributions of edema and subcutaneous adipose tissue are represented as a two-class Gaussian mixture model (GMM). In previous work, edema regions were segmented by selecting voxels with density values within the edema density distribution. This work improves upon the prior work by generating an adipose tissue mask without edema through a conditional generative adversarial network. The density distribution of the generated mask was imported into a Chan-Vese level set framework. Edema and subcutaneous adipose tissue are separated by iteratively updating their respective density distributions.

RESULTS

Validation results on 25 patients with edema showed that the segmentation accuracy significantly improved. Compared to GMM, the average Dice Similarity Coefficient increased from 56.0 to 61.7% ([Formula: see text]) and the relative volume difference decreased from 36.5 to 30.2% ([Formula: see text]).

CONCLUSION

The generated adipose tissue density prior improved edema segmentation accuracy. Accurate edema volume measurement may prove clinically useful.

Для цитирования: Liu Jianfei, Shafaat Omid, Bhadra Sayantan, Parnell Christopher, Harris Ayden, Summers Ronald M. Improved subcutaneous edema segmentation on abdominal CT using a generated adipose tissue density prior.. International journal of computer assisted radiology and surgery. 2024. DOI: 10.1007/s11548-023-03051-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.