Outcomes of biosynthetic collagen prostheses with comparison to cryopreserved arterial homografts for bypass reconstruction in infrainguinal vascular graft infections.

Zerdzitzki Matthaeus, Pfister Karin, Schierling Wilma, Zeman Florian, Toepel Ingolf, Steinbauer Markus, Betz Thomas

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Managing infrainguinal vascular graft infections (VGI) in bypass reconstruction is complex. Although an autologous vein is the preferred graft material, alternative conduits are required when autologous veins are unavailable. This study aimed to compare the efficacy of cryopreserved arterial homografts and biosynthetic glutaraldehydemodifiedovine collagen grafts (Omniflow II) for the treatment of infrainguinal VGI.

METHODS

The study was retrospective across two centers and included patients with infrainguinal VGI treated with cryopreserved arterial homografts or Omniflow II grafts between 2009 and 2019. Freedom from reinfection, primary patency rates, amputation-free survival, and overall survival were analyzed using 5-year Kaplan-Meier estimates.

RESULTS

Overall, 63 patients with infrainguinal VGI were treated with either Omniflow II grafts (n = 34) or cryopreserved arterial homografts (n = 29). At 5 years, freedom from reinfection was 97.1% for Omniflow II grafts and 93.1% for cryopreserved arterial homografts (p = .4). Primary patency was 50% for Omniflow II grafts and 55.2% for the cryopreserved arterial homografts (p = .5). Amputation-free survival was 52.9% for Omniflow II grafts and 55.2% for cryopreserved arterial homografts (p = .7). No graft degeneration or graft ruptures were observed during the follow-up.

CONCLUSIONS

This study suggests that biosynthetic grafts are viable and accessible alternatives for traditional graft materials, offering similar efficacy and ease of use. Although autologous vein grafts remain the gold standard for VGI management, biosynthetic grafts may serve as a viable alternatives to cryopreserved arterial homografts in the treatment of infrainguinal VGIs.

Для цитирования: Zerdzitzki Matthaeus, Pfister Karin, Schierling Wilma, Zeman Florian, Toepel Ingolf, Steinbauer Markus, Betz Thomas. Outcomes of biosynthetic collagen prostheses with comparison to cryopreserved arterial homografts for bypass reconstruction in infrainguinal vascular graft infections.. Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society. 2025. DOI: 10.1177/14574969251320721.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.