Vitreous fluid levels of beta-amyloid((1-42)) and tau in patients with retinal diseases.

Yoneda Shinji, Hara Hideaki, Hirata Akira, Fukushima Mikiko, Inomata Yasuya, Tanihara Hidenobu

СтатьяПеревод в очереди

Аннотация

PURPOSE: A decrease in beta-amyloid(1-42) (Abeta42) and an increase in tau in the cerebrospinal fluid are reported to be characteristic phenomena in Alzheimer's disease patients. To test the idea that Abeta42 and tau contribute to the development of retinal diseases, we measured Abeta42 and tau concentrations in the vitreous fluid from patients with macular hole (n = 13), diabetic retinopathy (n = 15), or glaucoma concurrent with other ocular diseases (n = 8).

METHODS

Vitreous samples were collected from patients who underwent vitrectomy, and sensitive and specific enzyme-linked immunosorbent assays were used to determine the concentrations of Abeta42 and tau.

RESULTS

By comparison with the levels in the control macular-hole patients (33.9 +/- 7.1 pg/ml for Abeta42; 3.3 +/- 3.2 pg/ml for tau), there was a significant decrease in the Abeta42 level and a significant increase in the tau level in patients with diabetic retinopathy (1.8 +/- 1.9 pg/ml for Abeta42, P = 0.002; 153.7 +/- 71.6 pg/ml for tau, P = 0.041) or glaucoma concurrent with other ocular diseases (2.8 +/- 1.8 pg/ml for Abeta42, P = 0.006; 113.6 +/- 43.1 pg/ml for tau, P = 0.023).

CONCLUSIONS

Our findings indicate the possibility of a role for Abeta42 and tau in the pathogenesis of some retinal diseases.

Для цитирования: Yoneda Shinji, Hara Hideaki, Hirata Akira, Fukushima Mikiko, Inomata Yasuya, Tanihara Hidenobu. Vitreous fluid levels of beta-amyloid((1-42)) and tau in patients with retinal diseases.. Japanese journal of ophthalmology. 2005. DOI: 10.1007/s10384-004-0156-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.