MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1748-605x/aea2fc

Медицинская библиотека · Biomedical materials (Bristol, England) · 2026

MnO2-loaded hydrogel nerve guidance conduit for peripheral nerve regeneration: anin vivostudy in the rat sciatic nerve defect model.

Wang Juan, Pan Liang, Gu Jiahe, Wang Shang, Zhou Dan, Wang Qian, Liu Yue, Feng Yu, Ma Yongbin, Zhao Kai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Peripheral nerve defect repair remains a clinical challenge. Nerve guidance conduits (NGCs) are potential alternatives to autografts, but their performance can be compromised by the oxidative and inflammatory microenvironment after injury. Here, we fabricated MnO2-loaded hydrogel NGCs at concentrations of 10, 50, and 100 μg ml-1and evaluated them in a rat model of a 10-mm sciatic nerve defect. Among the three concentrations, the MnO2@NMgel-10 (10 μg ml-1) group yielded a higher sciatic functional index, denser and more orderly regenerated nerve tissue, and less gastrocnemius muscle atrophy than the hydrogel-only and higher-dose conduit groups. Early tissue analysis showed that the MnO2@NMgel-10 group exhibited increased infiltration of CD86+CD206+cells, upregulated expression of IL-10, and significantly downregulated expression of IL-1β, TNF-α, and 4-HNE. Furthermore, the MnO2@NMgel-10 group showed satisfactory biosafety and biocompatibility. These findings reveal a non-monotonic concentration response and preliminarily confirm the feasibility of low-dose MnO2-functionalized hydrogel NGCs for repairing peripheral nerve defects, providing new insights into the application of MnO2as a supplementary material for NGC fabrication.

Для цитирования: Wang Juan, Pan Liang, Gu Jiahe, Wang Shang, Zhou Dan, Wang Qian, Liu Yue, Feng Yu, Ma Yongbin, Zhao Kai. MnO2-loaded hydrogel nerve guidance conduit for peripheral nerve regeneration: anin vivostudy in the rat sciatic nerve defect model.. Biomedical materials (Bristol, England). 2026. DOI: 10.1088/1748-605x/aea2fc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.