MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sipas.2022.100154

Медицинская библиотека · Surgery in practice and science · 2022

High flow cooled air can decrease brain temperature without injuring the snout or brain in Swine.

Stonko David P, Richmond Michael J, Edwards Joseph, Abdou Hossam, Treffalls Rebecca, Elansary Noha, Patel Neerav, Badjatia Neeraj, Jewhurst Kyle, Dupnik Michaelina, DiMatteo Kristian, Myers Ryan, Morrison Jonathan J

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Targeted temperature management plays an important role in the treatment of myriad critical illnesses. Non-invasive, quick-onset options for isolated brain temperature control remain lacking. The goal of this study was to assess the safety and efficacy of a novel intranasal high flow cooled air device using a large animal model.

METHODS

Yorkshire swine were instrumented with temperature probes in the rectum, brain, ear, and snout, and a novel intranasal cooled air device was applied to half. The primary outcome was effectiveness of brain and snout cooling by the study device. Secondary outcomes included tympanic cooling and absence of rectal cooling, CT, CT perfusion, and histologic evidence of injury in the short- and medium-term.

RESULTS

10 animals (54.7 kgs.+/- 19.4 SD) underwent non-survival evaluation, 3 underwent delayed evaluation (56.1 kgs.+/-6.4). From baseline to cooling period, intranasal (38.1 °C vs. 34.9 °C, p = 0.01), intracranial (38.6 °C vs. 37.2 °C, p = 0.01) and tympanic temperatures (38.3 °C vs. 37.5 °C, p = 0.01) decreased, while rectal temperature remained unchanged.After cooling, nasal temperature (34.9 °C vs. 37.6 °C, p = 0.004) and intracranial temperatures (37.2 °C vs. 37.9 °C, p = 0.01) increased. Rectal temperatures remained unchanged. A mixed effects model showed association between temperature and study period (p<0.0001), temperature and probe location (p = 0.002), with interaction between study period and probe location (p<0.0001). There was no evidence of injury to the snout or CT cerebral perfusion metrics, or in histologic end points.

CONCLUSION

This novel, non-invasive, intranasal high flow cooled air device provides isolated brain and head cooling without any evidence injury in the short or medium term.

Для цитирования: Stonko David P, Richmond Michael J, Edwards Joseph, Abdou Hossam, Treffalls Rebecca, Elansary Noha, Patel Neerav, Badjatia Neeraj, Jewhurst Kyle, Dupnik Michaelina, DiMatteo Kristian, Myers Ryan, Morrison Jonathan J. High flow cooled air can decrease brain temperature without injuring the snout or brain in Swine.. Surgery in practice and science. 2022. DOI: 10.1016/j.sipas.2022.100154.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.