Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2011
Endorectal balloon reduces anorectal doses in post-prostatectomy intensity-modulated radiotherapy.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Smeenk Robert Jan, van Lin Emile N J Th, van Kollenburg Peter, McColl Gill M, Kunze-Busch Martina, Kaanders Johannes H A M
Аннотация
BACKGROUND AND PURPOSE: To investigate the effect of an endorectal balloon (ERB) on anal wall (Awall) and rectal wall (Rwall) doses in high-dose post-prostatectomy intensity-modulated radiotherapy (IMRT).
MATERIALS AND METHODS: For 20 patients, referred for salvage IMRT after prostatectomy for prostate cancer, two planning CT-scans were performed: one with and one without an air-filled ERB. A planning target volume (PTV) was defined, using international guidelines. Furthermore, the Awall and Rwall were delineated. In both the scans, IMRT plans were generated with a prescribed dose of 70 Gy. The mean dose (D(mean)), maximum dose, minimum dose, and volumes exposed to doses ranging from ≥ 20 to ≥ 70 Gy (V(20)-V(70)) to the Awall and Rwall were calculated. Finally, inner Rwall surface areas exposed to doses ranging from ≥ 20 to ≥ 70 Gy (A(20)-A(70)) were calculated. Dose-parameters were compared between plans with and without ERB.
RESULTS: All Awall parameters, except V(70), were significantly reduced by the ERB with an overall D(mean) reduction of 6 Gy. Absolute reductions in dose-volume parameters varied from 5% to 11%. Significantly reduced Rwall V(30), V(40), and A(40) were observed with ERB, irrespective of the target volume size.
CONCLUSION: ERB application significantly reduces Awall and to a lesser degree Rwall doses in high-dose post-prostatectomy IMRT.
MATERIALS AND METHODS: For 20 patients, referred for salvage IMRT after prostatectomy for prostate cancer, two planning CT-scans were performed: one with and one without an air-filled ERB. A planning target volume (PTV) was defined, using international guidelines. Furthermore, the Awall and Rwall were delineated. In both the scans, IMRT plans were generated with a prescribed dose of 70 Gy. The mean dose (D(mean)), maximum dose, minimum dose, and volumes exposed to doses ranging from ≥ 20 to ≥ 70 Gy (V(20)-V(70)) to the Awall and Rwall were calculated. Finally, inner Rwall surface areas exposed to doses ranging from ≥ 20 to ≥ 70 Gy (A(20)-A(70)) were calculated. Dose-parameters were compared between plans with and without ERB.
RESULTS: All Awall parameters, except V(70), were significantly reduced by the ERB with an overall D(mean) reduction of 6 Gy. Absolute reductions in dose-volume parameters varied from 5% to 11%. Significantly reduced Rwall V(30), V(40), and A(40) were observed with ERB, irrespective of the target volume size.
CONCLUSION: ERB application significantly reduces Awall and to a lesser degree Rwall doses in high-dose post-prostatectomy IMRT.