Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
Diagnostic Performance of PSMA PET/MRI in Characterizing LI-RADS 3 Observations in Patients with Cirrhosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Catalano Onofrio Antonio, Bhan Irun, Asmundo Luigi, Bradley William Robert, Fonderico Mattia, Zhang M Lisa, Mojtahed Amirkasra, Anderson Mark A, Herold Alexander, Hajati Azadeh, Pena-Trujillo Valeria, Caravan Peter D, Harrington Samantha G, Esfahani Shadi Abdar, Mahmood Umar, Elias Nahel, Walsh Elizabeth P, Pratt Daniel S, Scherrer Abigail B, Ellis Haley, Bethea Emily D, Sirlin Claude, Kambadakone Avinash Ramesh, Ryan David, Lau-Min Kelsey
Аннотация
Liver Imaging Reporting and Data System (LI-RADS) category 3 (LR-3) observations remain indeterminate and often result in repeated follow-up or biopsy. Prostate-specific membrane antigen (PSMA) is overexpressed in hepatocellular carcinoma (HCC) neovasculature and may serve as a useful imaging biomarker. This study aimed to evaluate whether [68Ga]Ga-PSMA-11 PET/MRI improved characterization of LR-3 observations in patients with cirrhosis compared with MRI alone. Methods: In this prospective study, conducted between March 2022 and June 2024, 19 patients with cirrhosis and 54 LR-3 observations identified on prior MRI underwent [68Ga]Ga-PSMA-11 PET/MRI. An observation was classified as HCC if it demonstrated focal 68Ga-PSMA uptake greater than background liver combined with at least 1 LI-RADS major or ancillary feature. The reference standard was histopathology or a follow-up MRI within 12 mo. Diagnostic metrics were calculated. Univariable logistic regression and decision tree analysis were performed to identify imaging predictors of malignancy. Results: Of the 54 LR-3 observations, 13 (24%) were confirmed as HCC and 41 (76%) as benign. [68Ga]Ga-PSMA-11 PET/MRI correctly identified 12 of 13 HCCs (sensitivity, 92%; 95% CI, 66.7-99.6) and 39 of 41 benign observations (specificity, 95%; 95% CI, 81.9-99.3). Overall diagnostic accuracy was 94%, with a positive predictive value of 86% and negative predictive value of 97%. Diagnostic performance was significantly better than MRI alone (McNemar test, P < 0.001). [68Ga]Ga-PSMA-11 uptake was the only significant imaging predictor of malignancy on univariable analysis (odds ratio, 5.7; P = 0.017). Decision tree analysis identified [68Ga]Ga-PSMA-11 uptake, observation size, and hepatobiliary phase hypointensity as principal discriminators. Conclusion: [68Ga]Ga-PSMA-11 PET/MRI demonstrates high diagnostic accuracy in differentiating malignant from benign LR-3 liver observations in patients with cirrhosis. This technique may reduce unnecessary follow-up imaging and biopsy. These results support further validation of [68Ga]Ga-PSMA-11 PET/MRI as a promising imaging approach for indeterminate liver observations.