MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/hae.70341

Медицинская библиотека · Haemophilia : the official journal of the World Federation of Hemophilia · 2026

Monitoring of Coagulation Potential of Efanesoctocog Alfa in Haemophilia A: Insights From Conventional and Global Hemostasis Assays.

Takeyama Masahiro, Nishida Yasuharu, Furukawa Shoko, Ogiwara Kenichi, Nogami Keiji

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Efanesoctocog alfa (Efa) is a high-sustained factor (F)VIII engineered to overcome von Willebrand factor (VWF)-dependent clearance, enabling once-weekly dosing. However, FVIII activity (FVIII:C) differs between the one-stage assay (OSA) and chromogenic substrate assay (CSA), and its relationship with global assays remains unclear.

AIM: To assess the procoagulant potential in people with haemophilia A (PwHA) treated with Efa using conventional and global assays.

METHODS

Plasma samples were collected from five PwHA treated with Efa.

FVIII: C was assayed using OSA (RevohemAPTT, PathromtinSL at two institutions) and CSA. Clot waveform analysis (CWA) using RevohemAPTT SLA and ThromboCheck APTT SLA, thrombin generation assay (TGA), and rotational thromboelastometry were performed. Apparent equivalent FVIII:C (app-eq-FVIII:C) was derived from reference curves for cross-assay comparison.

RESULTS

OSA-FVIII:C showed reagent- and site-dependent variability. Pathromtin-based FVIII:C aligned with Revohem-based values at one site but was 1.6-1.8-fold higher at the other. CSA values were higher; CSA/2.5 variably approximated OSA in this dataset. CWA increased consistently after administration, with Revohem-based assays higher than ThromboCheck-based assays, indicating reagent-dependent variation within CWA. TGA showed increased thrombin generation with interpatient variability, ranging from minimal to relatively marked increases; conversion to app-eq-FVIII:C was strongly parameter-dependent (time-to-Peak vs Peak-Th). Rotational thromboelastometry revealed heterogeneous responses, and app-eq-FVIII:C was frequently lower than OSA and CSA/2.5-derived values.

CONCLUSION

Efa demonstrated assay-detected post-infusion increases; however, FVIII:C measurement varied across platforms and parameters. In this small exploratory cohort, these findings support assay-specific validation and cautious interpretation of inter-platform differences, rather than definitive conclusions regarding optimal monitoring strategy or direct clinical decision-making.

Для цитирования: Takeyama Masahiro, Nishida Yasuharu, Furukawa Shoko, Ogiwara Kenichi, Nogami Keiji. Monitoring of Coagulation Potential of Efanesoctocog Alfa in Haemophilia A: Insights From Conventional and Global Hemostasis Assays.. Haemophilia : the official journal of the World Federation of Hemophilia. 2026. DOI: 10.1111/hae.70341.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.