INTRODUCTION

In the emergency department setting, it is essential to rapidly and accurately confirm correct endotracheal tube (ETT) placement. Ultrasound is an increasingly studied modality for identifying ETT location. However, there has been significant variation in techniques between studies, with some using the dynamic technique, while others use a static approach. This study compared the static and dynamic techniques to determine which was more accurate for ETT identification.

METHODS

We performed this study in a cadaver lab using three different cadavers to represent variations in neck circumference. Cadavers were randomized to either tracheal or esophageal intubation in equal proportions. Blinded sonographers then assessed the location of the ETT using either static or dynamic sonography. We assessed accuracy of sonographer identification of ETT location, time to identification, and operator confidence.

RESULTS

A total of 120 intubations were performed: 62 tracheal intubations and 58 esophageal intubations. The static technique was 93.6% (95% confidence interval [CI] [84.3% to 98.2%]) sensitive and 98.3% specific (95% CI [90.8% to 99.9%]). The dynamic technique was 92.1% (95% CI [82.4% to 97.4%]) sensitive and 91.2% specific (95% CI [80.7% to 97.1%]). The mean time to identification was 6.72 seconds (95% CI [5.53 to 7.9] seconds) in the static technique and 6.4 seconds (95% CI [5.65 to 7.16] seconds) in the dynamic technique. Operator confidence was 4.9/5.0 (95% CI [4.83 to 4.97]) in the static technique and 4.86/5.0 (95% CI [4.78 to 4.94]) in the dynamic technique. There was no statistically significant difference between groups for any of the outcomes.

CONCLUSION

This study demonstrated that both the static and dynamic sonography approaches were rapid and accurate for confirming ETT location with no statistically significant difference between modalities. Further studies are recommended to compare these techniques in ED patients and with more novice sonographers.

Для цитирования: Gottlieb Michael, Nakitende Damali, Sundaram Tina, Serici Anthony, Shah Shital, Bailitz John. Comparison of Static versus Dynamic Ultrasound for the Detection of Endotracheal Intubation.. The western journal of emergency medicine. 2018. DOI: 10.5811/westjem.2017.12.36714.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.