Eosinophilic peak counts in eosinophilic esophagitis : a retrospective study.
Аннотация
BACKGROUND
The histologic diagnosis of eosinophilic esophagitis (EoE) is based on finding >15 eosinophils/high power field (HPF) on any level within the squamous epithelium of the esophagus. However, this criterion is based on a consensus statement, and controversy remains about the exact number of eosinophils/HPF needed to diagnose EoE. We aimed to determine eosinophilic peak counts in esophageal, gastric, and duodenal biopsies from suspected EoE patients, investigate the correlation between eosinophilic peak counts at different biopsy locations, and determine inter-observer and intra-observer reliability in reporting eosinophilic peak counts.
METHODS
We selected 103 suspected EoE patients, who underwent an endoscopic procedure between June 1, 2010 and July 15, 2017. Eosinophilic peak counts in 1 HPF were obtained by a medical student and an experienced gastrointestinal pathologist.
RESULTS
Eosinophilic peak counts in suspected EoE patients are highly variable (esophagus : IQR 66-178, median 110 ; stomach : IQR 2-10, median 3 ; duodenum : IQR 16-44, median 25). No significant correlation was found between eosinophilic peak counts at different biopsy locations. The inter-observer and intra-observer correlation for reporting eosinophilic peak counts was in the nearperfect range (ρ ranged from 0.93 to 0.99, P<0.0001).
CONCLUSIONS
Our data suggest that the accuracy of determining eosinophilic peak counts is not influenced by the pathologist's experience. Therefore, variability in reporting eosinophilic peak counts is unlikely to influence the diagnostic accuracy of EoE. To further improve diagnostic accuracy, investigation of other histologic features observed in EoE is needed.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.