Surgical excision of BioZorb device eroding through the nipple-areolar complex one year postoperatively: A case report.

Ju Tammy, Tsai Jacqueline

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The recent use of placing a BioZorb device during breast conservation surgery has been shown to improve targeting of adjuvant radiation therapy by significantly reducing target volume to the breast. However, the risks of surgical and/or infectious complications related to a BioZorb placement are largely unknown. In this case report, we describe a patient who underwent BioZorb placement after breast lumpectomy for ductal carcinoma in situ (DCIS), who presented with repeated infections and eventual erosion of the BioZorb through her nipple-areolar complex (NAC), requiring surgical debridement and excision of her NAC and BioZorb 1 year postoperatively.

Для цитирования: Ju Tammy, Tsai Jacqueline. Surgical excision of BioZorb device eroding through the nipple-areolar complex one year postoperatively: A case report.. The breast journal. 2021. DOI: 10.1111/tbj.14168.