Treatment of encapsulated blebs with slit-lamp needling and subconjunctival interferon injection.

Mao Zhen, Liu Xing, Zhong Yimin, Cao Dan, Li Mei, Yu Fenfen

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the efficacy and safety of slit-lamp needle revision with subconjunctival interferon injection in eyes with encapsulated blebs.

PATIENTS AND

METHODS

We reviewed a series of 25 cases (27 eyes) in which primary needling with 5×105 IFN α-2b injection was performed for bleb encapsulation and analysed the results over a follow-up period of at least 12 months.

RESULTS

The mean time to development of encapsulated blebs after the surgery was 23.85 ± 10.66 days (9 to 60 days). The mean IOP decreased significantly from 22.51 ± 5.30 mm Hg at diagnosis of encapsulated blebs to 17.26±7.72 mmHg at the last visit (P = 0.009). Of the 27 eyes, 15 (55.56%) achieved a successful result, 10 (37.04%) were qualified for success and the remaining 2 (7.4%) were considered as failure. The qualified success group took 1.70 ± 0.67 antiglaucoma medications. No serious complications were detected.

CONCLUSION

The needling procedure associated with subconjuctival injection of IFN α-2b is a safe and effective method in treating encapsulated blebs.

Для цитирования: Mao Zhen, Liu Xing, Zhong Yimin, Cao Dan, Li Mei, Yu Fenfen. Treatment of encapsulated blebs with slit-lamp needling and subconjunctival interferon injection.. Eye science. 2011. DOI: 10.3969/j.issn.1000-4432.2011.03.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.