A hermetic wireless subretinal neurostimulator for vision prostheses.

Kelly Shawn K, Shire Douglas B, Chen Jinghua, Doyle Patrick, Gingerich Marcus D, Cogan Stuart F, Drohan William A, Behan Sonny, Theogarajan Luke, Wyatt John L, Rizzo Joseph F

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device.

Для цитирования: Kelly Shawn K, Shire Douglas B, Chen Jinghua, Doyle Patrick, Gingerich Marcus D, Cogan Stuart F, Drohan William A, Behan Sonny, Theogarajan Luke, Wyatt John L, Rizzo Joseph F. A hermetic wireless subretinal neurostimulator for vision prostheses.. IEEE transactions on bio-medical engineering. 2011. DOI: 10.1109/tbme.2011.2165713.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.