Magnetic resonance imaging vs. transvaginal ultrasound for cervical length assessment in the second half of pregnancy.

Brandão Rosieny Souza, Pires Claudio Rodrigues, de Souza Eduardo, Avanza Leonardo Luiz, Mattar Rosiane, Araujo Júnior Edward, Nardozza Luciano Marcondes Machado, Moron Antonio Fernandes

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The purpose of this cross-sectional study involving 42 women between 20 and 39 weeks gestation was to compare transvaginal ultrasound (TVUS) vs. magnetic resonance imaging (MRI) in the assessment of cervical length measurement during the second half of pregnancy and to evaluate the reproducibility of cervical measurements obtained through MRI. Cervical length was measured through TVUS by a single examiner. On the same day, all women also had MRI and cervical length was assessed by two independent blinded observers. There were no significant differences in the mean cervical length obtained through TVUS and MRI (paired t-test, p = 0.191). The Bland-Altman test indicated concordance between measurements obtained through methods as well as good intra- and interobserver reproducibility for MRI measurements. Intraclass correlation coefficient was 0.990 (95% confidence interval [CI]: 0.982 to 0.995; p < 0.001) for measurements performed using MRI by two different observers and 0.995 (95% CI: 0.991 to 0.997; p < 0.001) for measurements performed using the same method by a single operator. Cervical length measured through TVUS and MRI does not differ significantly. There is a good reproducibility of cervical measurements obtained through MRI.

Для цитирования: Brandão Rosieny Souza, Pires Claudio Rodrigues, de Souza Eduardo, Avanza Leonardo Luiz, Mattar Rosiane, Araujo Júnior Edward, Nardozza Luciano Marcondes Machado, Moron Antonio Fernandes. Magnetic resonance imaging vs. transvaginal ultrasound for cervical length assessment in the second half of pregnancy.. Ultrasound in medicine & biology. 2010. DOI: 10.1016/j.ultrasmedbio.2009.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.