MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_2063_18

Медицинская библиотека · Indian journal of ophthalmology · 2019

Diurnal variation in subfoveal and peripapillary choroidal vascularity index in healthy eyes.

Singh Sumit Randhir, Rasheed Mohammed Abdul, Goud Abhilash, Sahoo Niroj Kumar, Vupparaboina Kiran Kumar, Chhablani Jay

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report the diurnal variation in choroidal vascularity index (CVI) in subfoveal (SF-CVI) and peripapillary area in healthy eyes.

METHODS

The study was a cross-sectional study including 12 healthy subjects. Swept-source optical coherence tomography scans were taken at 9 am, 11 am, 1 pm, 3 pm, and 5 pm. Subfoveal choroidal thickness (SFCT) and CVI were calculated using automated segmentation techniques and previously validated algorithms. Systemic parameters including systolic blood pressure (SBP), diastolic blood pressure, mean arterial pressure, and mean ocular perfusion pressure were calculated and correlated with SFCT and CVI.

RESULTS

A total of 12 eyes (right eye) of 12 patients (mean age: 26 ± 3.77 years) were analyzed. The mean (±standard deviation) amplitude of SFCT and SF-CVI variation was 35.91 ± 14.8 μm (range, 15-69 μm) and 0.05 ± 0.02 (range, 0.02-0.08). The mean CVI showed a significant diurnal variation in the temporal quadrant of the peripapillary region (P = 0.02).

CONCLUSION

SFCT and SF-CVI showed a significant diurnal variation in amplitude (peak-trough analysis) and SF-CVI correlated well with SBP suggestive of a direct influence of blood pressure on choroidal vascularity. The mean peripapillary CVI in the temporal quadrant also showed a significant diurnal variation with no significant change in other quadrants.

Для цитирования: Singh Sumit Randhir, Rasheed Mohammed Abdul, Goud Abhilash, Sahoo Niroj Kumar, Vupparaboina Kiran Kumar, Chhablani Jay. Diurnal variation in subfoveal and peripapillary choroidal vascularity index in healthy eyes.. Indian journal of ophthalmology. 2019. DOI: 10.4103/ijo.ijo_2063_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.