CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction.

Hur Joonho, Park Sung Bin, Lee Jong Beum, Park Hyun Jeong, Chang In Ho, Kwon Jong Kyou, Kim Yang Soo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare radiation dose and image quality in regular, low, and ultralow-dose CT protocols, and to evaluate diagnostic performance of low-dose CT for urolithiasis.

MATERIALS AND

METHODS

Sixty-five patients with suspected urolithiasis underwent three different scans under the regular, low, and ultralow-dose protocols. The regular dose scans were reconstructed using filtered back projection and the low-dose scans were reconstructed using a statistical iterative reconstruction. The ultralow-dose scans were reconstructed using both techniques in addition to a knowledge-based IR. Effective radiation doses were compared. Objective image noise was assessed by measuring standard deviation of HU and subjective image assessment was performed with a 3- or 5-point scale. Diagnostic performance of the low-dose image was evaluated, using the regular dose image as a standard reference and the interobserver agreement between two reviewers with different levels of experience was calculated.

RESULTS

The effective radiation dose was significantly different in each protocol (p < 0.001) and estimated dose reduction of the low-dose and ultralow-dose protocols was 76.4% and 89.8%, respectively. The knowledge-based iterative reconstruction algorithm showed poorer subjective image quality than the regular and low-dose protocols, but it also had the least objective image noise. Overall, the low-dose image set showed a greater than 84% concordance rate and 100% in ureter stones larger than 3 mm. Interobserver agreement was substantial (kappa value = 0.61).

CONCLUSIONS

The knowledge-based IR can provide a better quality image while reducing radiation exposure under the same protocol. Furthermore, the diagnostic performance of the low-dose CT protocol is comparable to the regular dose scan.

Для цитирования: Hur Joonho, Park Sung Bin, Lee Jong Beum, Park Hyun Jeong, Chang In Ho, Kwon Jong Kyou, Kim Yang Soo. CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction.. Abdominal imaging. 2015. DOI: 10.1007/s00261-015-0411-2.