MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1539/joh.l8030

Медицинская библиотека · Journal of occupational health · 2009

Reliability of the proposed international classification of high-resolution computed tomography for occupational and environmental respiratory diseases.

Suganuma Narufumi, Kusaka Yukinori, Hering Kurt G, Vehmas Tapio, Kraus Thomas, Arakawa Hiroaki, Parker John E, Kivisaari Leena, Letourneux Marc, Gevenois Pierre A, Tuengerthal Siegfreud, Crane Michael D, Shida Hisao, Akira Masanori, Henry Daniel A, Nakajima Yasuo, Hiraga Yohmei, Itoh Harumi, Hosoda Yutaka

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We have developed a classification of high-resolution computed tomography (HRCT) images for screening, surveillance and epidemiological studies of respiratory diseases caused by occupational and environmental factors. The proposed classification consists of three parts: a guideline explaining the elements of the classification scheme, a reading sheet, and reference films to aid in assessing thin-section CT films. We assessed the reliability of the proposed classification system by blinded, independent trial reading.

MATERIALS AND

METHODS

Seven independent radiologists and pulmonologists performed a trial reading to measure the reliability of the classification system using HRCT films from 27 pneumoconiosis patients and 7 normal controls.

RESULTS

The agreement was moderate to good for rounded opacities (weighted kappa=0.68 and 0.64), irregular opacities (0.59, 0.48), honeycombing (0.65, 0.47), emphysema (0.76, 0.62) and large opacities (0.48, 0.52). Ground glass opacities (0.16, 0.20) showed poor to fair agreement. Intra-reader agreement of each of the seven readers was moderate to good (mean: weighted kappa=0.52-0.80) for parenchymal findings, but the agreement was relatively low (mean weighted kappa=0.52) for ground glass opacities.

CONCLUSION

The proposed classification is able to describe early dust-related fibrotic changes and provide a semi-quantitative description of the HRCT features of major fibrotic changes in the parenchyma and pleura. Reliability, as measured by inter-reader agreement, was satisfactory.

Для цитирования: Suganuma Narufumi, Kusaka Yukinori, Hering Kurt G, Vehmas Tapio, Kraus Thomas, Arakawa Hiroaki, Parker John E, Kivisaari Leena, Letourneux Marc, Gevenois Pierre A, Tuengerthal Siegfreud, Crane Michael D, Shida Hisao, Akira Masanori, Henry Daniel A, Nakajima Yasuo, Hiraga Yohmei, Itoh Harumi, Hosoda Yutaka. Reliability of the proposed international classification of high-resolution computed tomography for occupational and environmental respiratory diseases.. Journal of occupational health. 2009. DOI: 10.1539/joh.l8030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.