MedElevator Войти в исследования
← Поиск публикаций

DOI 10.22038/aojnmb.2019.12734

Медицинская библиотека · Asia Oceania journal of nuclear medicine & biology · 2019

Inaccuracy of Thyroid to Background Uptake Ratio in Evaluating Technetium-99m-pertechnetate Thyroid Uptake and Establishing an Improved Algorithm.

Wang Changyin, Zhao Yanfen, Shen Ying

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to explore the accuracy of thyroid to background uptake ratio (UR) in the evaluation of 99mTc-pertechnetate thyroid uptake (TcTU) and establishment of an improved algorithm.

METHODS

This study was conducted on the thyroid images of 322 patients with thyroid diseases and 67 controls. For the purpose of the study, URs of the images were calculated, and then corrected by standardized thyroid area size to establish a corrected uptake ratio (CUR). Subsequently, the accuracy between UR and CUR was compared.

RESULTS

The results of linear regression using weighted least squares (using TcTU as a dependent variable and CUR, UR, or thyroid area size as independent variables) showed that CUR (t=105.5, P=0.000), UR (t=31.9, P=0.000), and thyroid area size (t=15.9, P=0.000) are influential factors of TcTU. Furthermore, the standardized coefficient of CUR (β=0.983) was obviously higher than those of UR (β=0.851) and thyroid area size (β=0.629). The linear goodness-of-fit between CUR and TcTU (R=0.983) was better than that between UR and TcTU (R=0.851). In addition, the total concordance rate between CUR and TcTU (96.7%) was significantly higher than that between UR and TcTU (83.0%; χ2=42.9, P=0.000). Discordance rates of CUR in large thyroid area (1.4% vs. 13.4%, χ2=17.0, P=0.000) and small thyroid area (3.3% vs. 42.2 %, χ2=44.3, P=0.000), were significantly lower than that of UR. In the abnormal thyroid areas, the discordance rates of UR obviously increased as compared to those of CUR. The UR overestimated the thyroid uptake in small thyroid areas and underestimated it in large thyroid areas.

CONCLUSION

Based on the findings, CUR is more accurate than UR in measuring 99mTcO4- thyroid uptake; accordingly, it is more significant in the diagnosis of thyroid disease.

Для цитирования: Wang Changyin, Zhao Yanfen, Shen Ying. Inaccuracy of Thyroid to Background Uptake Ratio in Evaluating Technetium-99m-pertechnetate Thyroid Uptake and Establishing an Improved Algorithm.. Asia Oceania journal of nuclear medicine & biology. 2019. DOI: 10.22038/aojnmb.2019.12734.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.