Early experience with intensity modulated proton therapy for lung-intact mesothelioma: A case series.

Pan Hubert Y, Jiang Shengpeng, Sutton Jordan, Liao Zhongxing, Chance William W, Frank Steven J, Zhu X Ronald, Li Heng, Fontanilla Hiral P, Zhang Xiaodong, Gomez Daniel R

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to describe our experience implementing intensity modulated proton therapy (IMPT) for lung-intact malignant pleural mesothelioma (MPM), including patient selection, treatment planning, dose verification, and process optimization.

METHODS AND MATERIALS: Seven patients with epithelioid MPM were reviewed; 6 underwent pleurectomy, whereas 1 had biopsy alone. Four patients received IMPT and 3 received intensity modulated radiation therapy. Treatment plans for the other modality were created for dosimetric comparisons. Quality assurance processes included dose verification and robustness analysis. Image-guided setup was performed with the first isocenter, and couch shifts were applied to reposition to the second isocenter.

RESULTS

Treatment with IMPT was well tolerated and completed without breaks. IMPT plans were designed with 2 isocenters, 4 beams, and ≤64 energy layers per beam. Dose verification processes were completed in 3 hours. Total daily treatment time was approximately 45 minutes (20 minutes for setup and 25 minutes for delivery). IMPT produced lower mean doses to the contralateral lung, heart, esophagus, liver, and ipsilateral kidney, with increased contralateral lung sparing when mediastinal boost was required for nodal disease.

CONCLUSIONS

Our initial experience showed that IMPT was feasible for routine care of patients with lung-intact MPM.

Для цитирования: Pan Hubert Y, Jiang Shengpeng, Sutton Jordan, Liao Zhongxing, Chance William W, Frank Steven J, Zhu X Ronald, Li Heng, Fontanilla Hiral P, Zhang Xiaodong, Gomez Daniel R. Early experience with intensity modulated proton therapy for lung-intact mesothelioma: A case series.. Practical radiation oncology. 2015. DOI: 10.1016/j.prro.2014.11.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.