MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1001-5515.201607084

Медицинская библиотека · Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2017

[Automatic classification of first-episode, drug-naive schizophrenia with multi-modal magnetic resonance imaging].

Yang Yongzhe, Zhang Yue, Wu Fengchun, Lu Xiaobing, Ning Yuping, Huang Biao, Du Xin, Li Chengwei, Wang Kaixi, Wu Xiaoming, Wu Kai

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

A great number of studies have demonstrated the structural and functional abnormalities in chronic schizophrenia (SZ) patients. However, few studies analyzed the differences between first-episode, drug-naive SZ (FESZ) patients and normal controls (NCs). In this study, we recruited 44 FESZ patients and 56 NCs, and acquired their multi-modal magnetic resonance imaging (MRI) data, including structural and resting-state functional MRI data. We calculated gray matter volume (GMV), regional homogeneity (ReHo), amplitude of low frequency fluctuation (ALFF), and degree centrality (DC) of 90 brain regions, basing on an automated anatomical labeling (AAL) atlas. We then applied these features into support vector machine (SVM) combined with recursive feature elimination (RFE) to discriminate FESZ patients from NCs. Our results showed that the classifier using the combination of ReHo and ALFF as input features achieved the best performance (an accuracy of 96.97%). Moreover, the most discriminative features for classification were predominantly located in the frontal lobe. Our findings may provide potential information for understanding the neuropathological mechanism of SZ and facilitate the development of biomarkers for computer-aided diagnosis of SZ patients.

Для цитирования: Yang Yongzhe, Zhang Yue, Wu Fengchun, Lu Xiaobing, Ning Yuping, Huang Biao, Du Xin, Li Chengwei, Wang Kaixi, Wu Xiaoming, Wu Kai. [Automatic classification of first-episode, drug-naive schizophrenia with multi-modal magnetic resonance imaging].. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. 2017. DOI: 10.7507/1001-5515.201607084.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.