MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-020-07645-4

Медицинская библиотека · European radiology · 2021

Performance of PET imaging for the localization of epileptogenic zone in patients with epilepsy: a meta-analysis.

Niu Na, Xing Haiqun, Wu Meiqi, Ma Yanru, Liu Yimin, Ba Jiantao, Zhu Shikun, Li Fang, Huo Li

СтатьяМетаанализОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this meta-analysis was to estimate the clinical use value of 11C-FMZ and 18F-FDG in PET for the localization of epileptogenic zone and to provide evidence for practitioners' clinical decision-making.

METHODS

We searched PubMed and Embase in a time frame from inception to May 31, 2020. Studies utilizing FMZ or FDG-PET or FDG-PET/MRI used in patients with epilepsy, with EEG or surgical outcomes as the gold standard and corresponding outcomes such as concordance rates of PET or PET/MRI scan compared with reference standard, absolute numbers of participants with true-positive (TP), false-positive (FP), true-negative (TN), and false-negative (FN) results in FDG or FMZ PET. Pooled concordance rates, overall sensitivity, and specificity of 11C-FMZ-PET and 18F-FDG-PET were calculated.

RESULTS

In total, 44 studies met the inclusion criteria. The pooled concordance rates of FDG-PET, FMZ-PET, and FDG-PET/MRI coregistration compared with reference standard were 0.67 (95% CI: 0.60-0.73), 0.75 (95% CI: 0.57-0.93), and 0.93 (95% CI: 0.89-0.97), respectively. The concordance rate of 18F-FDG-PET in patients with temporal lobe epilepsy (TLE) was 0.79 (0.63; 0.92). The overall sensitivity and specificity of 18F-FDG-PET were 0.66 (95% CI: 0.58-0.73) and 0.71 (95% CI: 0.63-0.78), respectively. 11C-FMZ-PET displayed an overall sensitivity of 0.62 (95% CI: 0.49-0.73) and specificity of 0.73 (95% CI: 0.59-0.84).

CONCLUSIONS

Both 11C-FMZ PET and 18F-FDG PET are the choice of modalities for the localization of epileptogenic zone, especially when coregistered with MRI.

KEY POINTS: • 11C-FMZ-PET may be more helpful than 18F-FDG-PET in the localization of epilepsy foci. • Coregistration of FDG-PET and MRI is recommended in the localization of epileptogenic zone.

Для цитирования: Niu Na, Xing Haiqun, Wu Meiqi, Ma Yanru, Liu Yimin, Ba Jiantao, Zhu Shikun, Li Fang, Huo Li. Performance of PET imaging for the localization of epileptogenic zone in patients with epilepsy: a meta-analysis.. European radiology. 2021. DOI: 10.1007/s00330-020-07645-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.