Parapharyngeal space surgery via a transoral approach using a robotic surgical system: transoral robotic surgery.

Park Young Min, De Virgilio Armando, Kim Won Shik, Chung Hyun Pil, Kim Se-Heon

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

In transoral robotic surgery (TORS), if an endoscopic arm equipped with two integrated cameras is placed close to a lesion, a three-dimensionally magnified view of the operative field can be obtained. More important is that the operation can be performed precisely and bimanually using two instrument arms that can move freely within a limited working space. We performed TORS to treat several diseases that occur in the parapharyngeal space (PPS) and subsequently analyzed the treatment outcomes to confirm the validity of this procedure.

PATIENTS AND

METHODS

Between February 2009 and February 2012, 11 patients who required surgical treatment for the removal of a parapharyngeal lesion were enrolled in this prospective study. Nine patients received TORS for parapharyngeal tumor resection, and 2 patients with stylohyoid syndrome underwent TORS for resection of an elongated styloid process. The average age of the patients included in this study was 42 years. Five patients were male, and 6 patients were female.

RESULTS

TORS was successfully performed in all 11 patients. The average robotic system docking and operation times were 9.9 minutes (range, 5-24 minutes) and 54.2 minutes (range, 26-150 minutes), respectively. Patients were able to swallow normally the day after the operation. The average blood loss during the robotic operation was minimal (11.8 mL). The average hospital stay was 2.6 days. There were no significant complications in the perioperative or postoperative period. All patients were extremely satisfied with their cosmetic outcomes.

CONCLUSIONS

PPS surgery via a transoral approach using a robotic surgical system is technically feasible and secures a better cosmetic outcome than the transcervical, transparotid, or transmandibular approach. This new surgical method is safe and effective for benign diseases of the PPS.

Для цитирования: Park Young Min, De Virgilio Armando, Kim Won Shik, Chung Hyun Pil, Kim Se-Heon. Parapharyngeal space surgery via a transoral approach using a robotic surgical system: transoral robotic surgery.. Journal of laparoendoscopic & advanced surgical techniques. Part A. 2013. DOI: 10.1089/lap.2012.0197.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.