Establishing Protocol-based Dose Metrics for Common Abdomen and Pelvis Computed Tomography Protocols.

Dalah Entesar Zawam, Alsuwaidi Jamila Salam, AlKtebi Reem Salim, AlMulla Muna Abdellatif Ali, Gupta Priyank

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: The majority of the existing diagnostic reference levels (DRLs) that have been established for computed tomography (CT) are based on various anatomical locations, such as the head, chest, abdomen, etc. However, DRLs are initiated to improve radiation protection by conducting a comparison of similar examinations with similar objectives. The aim of this study was to explore the feasibility of establishing dose baselines based on common CT protocols for patients who underwent enhanced CT abdomen and pelvis exams.

METHODS

Dose length product total (tDLPs), volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), effective dose (E), and scan acquisition parameters for a total of 216 adult patients, who underwent an enhanced CT abdomen and pelvis exams over a one-year period, were obtained and retrospectively analyzed. Spearman coefficient and one-way ANOVA tests were used to check significant differences between dose metrics and the different CT protocols.

RESULTS

The data exhibited 9 different CT protocols to acquire an enhanced CT abdomen and pelvis exam at our institute. Out of these, 4 were found more common, i.e., CT protocols were acquired for a minimum of 10 cases. Triphasic liver demonstrated the highest mean and median tDLPs across all 4 CT protocols. Triphasic liver protocol registered the highest E followed by gastric sleeve protocol with a mean of 28.7 and 24.7 mSv, respectively. Significant differences (p < 0.0001) were found between the tDLPs of anatomical location and the CT protocol.

CONCLUSION

Evidently, wide variability exists across CT dose indices and patient dose metrics relying on anatomical-based dose baseline, i.e., DRLs. Patient dose optimizations require establishing dose baselines based on CT protocols rather than the anatomical location.

Для цитирования: Dalah Entesar Zawam, Alsuwaidi Jamila Salam, AlKtebi Reem Salim, AlMulla Muna Abdellatif Ali, Gupta Priyank. Establishing Protocol-based Dose Metrics for Common Abdomen and Pelvis Computed Tomography Protocols.. Current medical imaging. 2024. DOI: 10.2174/1573405620666230522151357.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.