Performance of Wide-Angle Tomosynthesis with Synthetic Mammography in Comparison to Full Field Digital Mammography.

Khanani Sadia, Hruska Carrie, Lazar Agnes, Hoernig Mathias, Hebecker Axel, Obuchowski Nancy

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The purpose of this study was to test for superiority of wide-angle digital breast tomosynthesis plus synthetic mammography (Insight 2D) in comparison to full-field digital mammography (FFDM).

MATERIALS AND

METHODS

In this study, twenty readers interpreted 350 screening and diagnostic cases of wide-angle digital breast tomosynthesis (DBT) plus Insight 2D and FFDM in two separate reading sessions separated by at least a 6-week washout period. Breast-level estimates of the area under the curve and sensitivity along with subject-level recall rate were measured and compared between wide-angle DBT plus Insight 2D and FFDM. The same measures were also assessed for dense breasts. A hierarchical analysis plan was used to control the study's type I error rate at 0.05.

RESULTS

The mean breast-level area under the curve for distinguishing breasts with cancer from non-cancer breasts was 0.893 with DBT plus Insight 2D versus 0.837 with FFDM, showing superiority of DBT plus Insight 2D (p < 0.001). Breast-level sensitivity was significantly superior for DBT plus Insight 2D in comparison to FFDM (0.852 vs. 0.805, p = 0.043). Subject-level recall rate for DBT plus Insight 2D was significantly lower in comparison to FFDM (0.344 vs. 0.473, p < 0.001). For dense breasts, the readers' accuracy with DBT plus Insight 2D was superior to their accuracy with FFDM (0.875 vs. 0.830, p = 0.026), and their recall rate was significantly lower for DBT plus Insight 2D in comparison to FFDM (0.338 vs. 0.441, p = 0.003).

CONCLUSION

Reader performance with wide-angle DBT plus Insight 2D is superior to that with FFDM, showing significantly higher breast-level accuracy and sensitivity and significantly lower recall rates.

Для цитирования: Khanani Sadia, Hruska Carrie, Lazar Agnes, Hoernig Mathias, Hebecker Axel, Obuchowski Nancy. Performance of Wide-Angle Tomosynthesis with Synthetic Mammography in Comparison to Full Field Digital Mammography.. Academic radiology. 2022. DOI: 10.1016/j.acra.2022.03.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.