Journal of neurointerventional surgery · 2020
Predictive score for complete occlusion of intracranial aneurysms treated by flow-diverter stents using machine learning.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Guédon Alexis, Thépenier Cédric, Shotar Eimad, Gabrieli Joseph, Mathon Bertrand, Premat Kévin, Lenck Stéphanie, Degos Vincent, Sourour Nader, Clarençon Frédéric
Аннотация
BACKGROUND: Complete occlusion of an intracranial aneurysm (IA) after the deployment of a flow-diverter stent is currently unpredictable. The aim of this study was to develop a predictive occlusion score based on pretreatment clinical and angiographic criteria.
METHODS: Consecutive patients with ≥6 months follow-up were included from 2008 to 2019 and retrospectively analyzed. Each IA was evaluated using the Raymond-Roy occlusion classification (RROC) and dichotomized as occluded (A) or residual (B/C); 80% of patients were randomly assigned to the training sample. Feature selection and binary outcome prediction relied on logistic regression and threshold maximizing class separation selected by a CART tree algorithm. The feature selection was addressed by a genetic algorithm selected from the 30 pretreatment available variables.
RESULTS: The study included 146 patients with 154 IAs. Feature selection yielded a combination of six variables with a good cross-validated accuracy on the test sample, a combination we labeled DIANES score (IA diameter, indication, parent artery diameter ratio, neck ratio, side-branch artery, and sex). A score of more than -6 maximized the ability to predict RROC=A with sensitivity of 87% (95% CI 79% to 95%) and specificity of 82% (95% CI 64% to 96%) in the training sample. Accuracy was 86% (95% CI 79% to 94%). In the test sample, sensitivity and specificity were 89% (95% CI 77% to 98%) and 60% (95% CI 33% to 86%), respectively. Accuracy was 81% (95% CI 69% to 91%).
CONCLUSION: A score was developed as a grading scale for prediction of the final occlusion status of IAs treated with a flow-diverter stent.
METHODS: Consecutive patients with ≥6 months follow-up were included from 2008 to 2019 and retrospectively analyzed. Each IA was evaluated using the Raymond-Roy occlusion classification (RROC) and dichotomized as occluded (A) or residual (B/C); 80% of patients were randomly assigned to the training sample. Feature selection and binary outcome prediction relied on logistic regression and threshold maximizing class separation selected by a CART tree algorithm. The feature selection was addressed by a genetic algorithm selected from the 30 pretreatment available variables.
RESULTS: The study included 146 patients with 154 IAs. Feature selection yielded a combination of six variables with a good cross-validated accuracy on the test sample, a combination we labeled DIANES score (IA diameter, indication, parent artery diameter ratio, neck ratio, side-branch artery, and sex). A score of more than -6 maximized the ability to predict RROC=A with sensitivity of 87% (95% CI 79% to 95%) and specificity of 82% (95% CI 64% to 96%) in the training sample. Accuracy was 86% (95% CI 79% to 94%). In the test sample, sensitivity and specificity were 89% (95% CI 77% to 98%) and 60% (95% CI 33% to 86%), respectively. Accuracy was 81% (95% CI 69% to 91%).
CONCLUSION: A score was developed as a grading scale for prediction of the final occlusion status of IAs treated with a flow-diverter stent.