MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2020-016748

Медицинская библиотека · Journal of neurointerventional surgery · 2020

Predictive score for complete occlusion of intracranial aneurysms treated by flow-diverter stents using machine learning.

Guédon Alexis, Thépenier Cédric, Shotar Eimad, Gabrieli Joseph, Mathon Bertrand, Premat Kévin, Lenck Stéphanie, Degos Vincent, Sourour Nader, Clarençon Frédéric

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Complete occlusion of an intracranial aneurysm (IA) after the deployment of a flow-diverter stent is currently unpredictable. The aim of this study was to develop a predictive occlusion score based on pretreatment clinical and angiographic criteria.

METHODS

Consecutive patients with ≥6 months follow-up were included from 2008 to 2019 and retrospectively analyzed. Each IA was evaluated using the Raymond-Roy occlusion classification (RROC) and dichotomized as occluded (A) or residual (B/C); 80% of patients were randomly assigned to the training sample. Feature selection and binary outcome prediction relied on logistic regression and threshold maximizing class separation selected by a CART tree algorithm. The feature selection was addressed by a genetic algorithm selected from the 30 pretreatment available variables.

RESULTS

The study included 146 patients with 154 IAs. Feature selection yielded a combination of six variables with a good cross-validated accuracy on the test sample, a combination we labeled DIANES score (IA diameter, indication, parent artery diameter ratio, neck ratio, side-branch artery, and sex). A score of more than -6 maximized the ability to predict RROC=A with sensitivity of 87% (95% CI 79% to 95%) and specificity of 82% (95% CI 64% to 96%) in the training sample. Accuracy was 86% (95% CI 79% to 94%). In the test sample, sensitivity and specificity were 89% (95% CI 77% to 98%) and 60% (95% CI 33% to 86%), respectively. Accuracy was 81% (95% CI 69% to 91%).

CONCLUSION

A score was developed as a grading scale for prediction of the final occlusion status of IAs treated with a flow-diverter stent.

Для цитирования: Guédon Alexis, Thépenier Cédric, Shotar Eimad, Gabrieli Joseph, Mathon Bertrand, Premat Kévin, Lenck Stéphanie, Degos Vincent, Sourour Nader, Clarençon Frédéric. Predictive score for complete occlusion of intracranial aneurysms treated by flow-diverter stents using machine learning.. Journal of neurointerventional surgery. 2020. DOI: 10.1136/neurintsurg-2020-016748.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.