MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinimag.2020.10.004

Медицинская библиотека · Clinical imaging · 2020

Is specimen radiography still necessary in patients with non-palpable breast cancer undergoing breast-conserving surgery using radioactive I-125 seed localization?

van Riet Yvonne E, Schipper Robert-Jan, van Merrienboer Franca, Orsini Ricardo G, Bloemen Johanne G, Jansen Frits H, Nieuwenhuijzen Grard A P

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the diagnostic performance for margin assessment of specimen radiography (SR) in breast conserving surgery (BCS) using radioactive I125-seed localization (RSL).

METHODS

The clinical, radiographic and histopathological data of women who underwent BCS after pre-operative RSL with intraoperative SR during nine consecutive years were analyzed. The histological margin and radiographic margin outcomes on SR were compared and results of intraoperative re-excisions were investigated.

RESULTS

A consecutive series of 448 women with invasive carcinoma (n = 211), ductal carcinoma in situ (DCIS) (n = 79) and a combination of DCIS and invasive carcinoma (n = 158) were included. The median minimal margins for the radiological masses and microcalcifications measured on SR were 14 mm and 11 mm, respectively. Based on a radiological cut-off SR margin value of 1 mm, the overall sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were 21.0%, 95.0%, 26.0%, and 94.0%, respectively. The area under the receiver-operating curve was 0.73. Intraoperative re-excisions based on SR were performed in 31 (6.9%) patients; histopathological examination of the additional excised tissue revealed DCIS or invasive carcinoma in 6 (19.4%) patients. Hence, SR was beneficial for 6/448 patients (1.3%), and unnecessary intraoperative re-excisions were performed in 20/448 patients (4.5%). The number need to treat is 75; this implies that per 75-SR one resection with involved margins is prevented.

CONCLUSION

SR has a moderate diagnostic performance for margin involvement using RSL. A more accurate intraoperative margin assessment tool is warranted.

Для цитирования: van Riet Yvonne E, Schipper Robert-Jan, van Merrienboer Franca, Orsini Ricardo G, Bloemen Johanne G, Jansen Frits H, Nieuwenhuijzen Grard A P. Is specimen radiography still necessary in patients with non-palpable breast cancer undergoing breast-conserving surgery using radioactive I-125 seed localization?. Clinical imaging. 2020. DOI: 10.1016/j.clinimag.2020.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.