Clinical neuroradiology · 2014

Diagnostic Efficacy of Conventional MRI Pulse Sequences in the Detection of Lesions Causing Internuclear Ophthalmoplegia in Multiple Sclerosis Patients.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

McNulty J P, Lonergan R, Brennan P C, Evanoff M G, O'Laoide R, Ryan J T, Tubridy N

Аннотация

PURPOSE: The purpose of this study was to investigate the diagnostic efficacy of a range of conventional magnetic resonance imaging (MRI) pulse sequences in the identification of internuclear ophthalmoplegia (INO) caused by medial longitudinal fasciculus (MLF) lesions in multiple sclerosis patients using a receiver-operating characteristic (ROC) methodology.

METHODS: A total of 15 clinically confirmed INO and 15 control subjects underwent conventional MRI at 1.5 T consisting of T2-weighted, proton density (PD)-weighted, and fluid-attenuated inversion recovery (FLAIR) sequences, following full institutional approval. A free-response, multiple-reader multiple-case design ROC study was used to evaluate the diagnostic efficacy of each sequence. All imaging sequences were evaluated by 10 board-certified neuroradiologists. Area under the curve (AUC), sensitivity, and specificity were analysed statistically for all three pulse sequences using repeated-measures analyses of variance and post-test analysis using Bonferroni's multiple comparison test of differences.

RESULTS: No significant AUC differences were found between the three sequences (p = 0.0697), with T2 recording the highest AUC (0.8346). Sensitivity differences between PD (0.7927) and FLAIR (0.6329) were significant (p < 0.05). Non-significant differences were also evident between T2 and FLAIR (p = 0.0511). The specificity analysis revealed an overall difference (p = 0.0005), with specific inter-sequence differences shown between T2 and PD (p < 0.05) and PD and FLAIR (p < 0.001) with the PD values being lower than those provided with the other two sequences.

CONCLUSION: T2-weighted axial imaging through the MLF region resulted in the greatest overall diagnostic efficacy when viewing a combination of mean AUC, sensitivity, and specificity, in terms of the identification of INO-causing lesions.