Comparison of embolic agents used in uterine artery embolisation: a systematic review and meta-analysis.

Das Raj, Champaneria Rita, Daniels Jane P, Belli Anna-Maria

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

PURPOSE: This study was designed to undertake systematic review and meta-analysis of published comparative trials comparing embolic agents used in uterine artery embolisation (UAE) for uterine leiomyomata.

METHODS

Systematic literature searches were performed in MEDLINE, Embase, PubMed, and Cochrane Central databases from database inception to July 2012. Randomised and nonrandomised trials comparing two or more embolic agents used in UAE were included. Assessment included five widely used embolic agents: nonspherical polyvinyl alcohol (PVA) (Contour PVA, Boston Scientific or PVA Cook Medical); spherical PVA (Contour SE, Boston Scientific); acrylamido PVA (Beadblock, Biocompatibles, Terumo); tris-acryl gelatin microspheres (TAGM) (Embospheres, Merit Medical Inc); and polyzene-F hydrogel microspheres (Embozenes, CeloNova Biosciences). Outcomes assessed included: quality of life (QOL), assessment, magnetic resonance imaging (MRI), uterine and fibroid volumes and degrees of MRI fibroid enhancement and devascularisation. A total of 262 citations were reviewed with 5 randomised, controlled trials involving 295 women and 5 non-RCTs involving 617 women included.

RESULTS

No evidence of superiority of any embolic agent was demonstrated. Meta-analysis was performed between TAGM (Embospheres) and spherical PVA microspheres. Two RCTs found a trend toward greater uterine and dominant fibroid volume reductions with Embospheres but the combined differences were not statistically significant (p = 0.78 and p = 0.94 respectively). Embospheres demonstrated greater percentage fibroid devascularisation than spherical PVA (p = 0.039).

CONCLUSIONS

This study confirms that the current evidence demonstrates superiority of Embospheres over spherical PVA but no reported differences in outcomes between any of the other agents. Comparison of embolic agents was limited by lack of RCT data and further research is warranted.

Для цитирования: Das Raj, Champaneria Rita, Daniels Jane P, Belli Anna-Maria. Comparison of embolic agents used in uterine artery embolisation: a systematic review and meta-analysis.. Cardiovascular and interventional radiology. 2013. DOI: 10.1007/s00270-013-0790-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.