m+Medelevator.RU
← Поиск публикаций
Building and environment · 2026

Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.

СтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhao Yuanzhe, Li Weihao, Bergmann Jeroen Hm

Аннотация

Accurate, real-time estimation of core body temperature (CBT) during physical activity is essential for monitoring heat strain and mitigating the risk of heat-related illness under hot environmental conditions. Although numerous data-driven algorithms using wearable sensors have been proposed, their practical reliability remains unclear due to substantial methodological heterogeneity and the absence of standardized evaluation. This study combined a systematic review with a standardized quantitative benchmark. A total of 38 studies employing non-invasive inputs for CBT estimation were identified. Of these, 14 eligible models, including Kalman filter-based methods, statistical models, and machine-learning approaches, were re-implemented and evaluated under identical preprocessing and evaluation settings using two independent datasets: Dataset 1 (treadmill walking, n = 16 ) and Dataset 2 (cycling, n = 13 ). The benchmark revealed notable differences between originally reported performance and reproduced performance under standardized conditions. For the widely used heart-rate-based extended Kalman filter, the root mean square error (RMSE) increased from typically reported values of ∼ 0.21-0.41  ∘ C to 0.41  ∘ C on Dataset 1 and 0.66  ∘ C on Dataset 2. Incorporating skin temperature improved tracking accuracy in some configurations, but performance gains were highly dependent on measurement site and dataset. Sensitivity for detecting elevated CBT ( ≥ 38.0  ∘ C) varied markedly across methods, particularly for the cycling protocol. In conclusion, no single CBT estimation approach consistently outperformed others across all settings. Heart-rate-only models provided a stable baseline under limited sensing conditions, whereas multimodal approaches offered conditional benefits in more controlled scenarios. This work establishes a standardized benchmark framework to support fair comparison, method selection, and future development of (wearable) CBT estimation technologies.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты